5.9
DIGITAL OUT
With Pin 4 (out), the user has a configurable switching output.
It can be defined as a single switching point (threshold) or a window. Pin 4 is activated when the value (point
or window) is exceeded or not reached (active high or active low depending on the setting).
The switching points can only be placed inside the active, preset measuring field (note SCALE OUT). There is
a hysteresis
1
for a reliable switching signal.
The window must be larger than “Minimal switching window” according to the sensors data sheet.
5.9.1
DIGITAL OUT
Whether Pin 4 is to be operated as a
threshold
(with a switch point) or as a
window
(window function) is
defined here.
5.9.2
SWITCH POINT
The switch point is selected in mm using the arrow keys. The point must lie within the measuring range
(between start of measuring range Sdc
and end of measuring range Sde
-2x hysteresis
).
1
According to data sheet chapter 6.1
S
ig
n
a
l
h
ig
h
S
ig
n
a
l
lo
w
SWITCH POINT
WINDOW P1
WINDOW P2
WINDOW
Function Distance: Point
Function Distance: Window
0 mm
S
ig
n
a
l
h
ig
h
S
ig
n
a
l
lo
w
0 mm
Sensor R2
level
Sensor R2
level
Hysteresis
Hysteresis
Hysteresis
Ou
tp
u
t
le
v
e
l:
Ak
tiv
Hi
g
h
Ou
tp
u
t
le
v
e
l:
A
k
ti
v
L
o
w
Ou
tp
u
t
le
v
e
l:
Ak
tiv
L
o
w
Ou
tp
u
t
le
v
e
l:
A
k
ti
v
Hi
g
h
Содержание OM70
Страница 1: ...Operating instructions OM70 multi spot ...