Function of the Teach button
With the Teach button function (
Local User Interface
), you have the option of specifying the
mode of the Teach button. You have a choice between the
Xpert
(factory setting) and
Xpress
modes. The mode is selected via the IO-Link.
Adjustable parameters in the
Xpert
mode:
n
Analog measurement field
n
Zero position
n
Resetting the sensor to the factory settings
For more information on the operation of the Teach button in the
Xpert
mode, see
.
Adjustable parameters in the
Xpress
mode:
n
Zero position
The Teach button is automatically deactivated after 5 min (the timeout can be parameterized via
IO-Link).
Teaching the zero position (in the
Xpress
mode)
Instruction:
a) Place the measurement object at the desired position for the zero position.
b) Keep the Teach button pressed for 2 seconds.
ü
Green LED blinks with 2 Hz.
Result:
ü
Teach-In ok: Sensor goes back to the operating mode.
ü
Teach-in not OK: Green and yellow LEDs blink simultaneously with 8 Hz.
IO-Link parameter: Teach button (Local User Interface)
Parameter name
Values
Description
Teach Mode Settings.Local Teach
Mode
Xpert,
Xpress
Selecting the mode for the Teach button
Teach Lock Settings.Button Time Out -
Enter the time period (Timeout) after which the
Teach button should be deactivated after a
teach-in process (in min). With a value of
0
, the
Teach button is always activated. With a value
of
255 (0xFF)
, the Teach button is perma-
nently deactivated.