3.4
Operating and display elements
3.4.1
Sensor LEDs
Des.
Illuminated
Blinking
POWER
Green
Sensor ready for operation
-
OUTPUT
Yellow
No valid signal within the measurement
range
Critical signal quality
In the factory settings, the
OUTPUT
(pin 4), and thus also the yellow LED, follows the function
of the alarm output. Alternatively, you can select the function of the switching output for the
OUTPUT
and the yellow LED.
3.4.2
Teach button
Instead of parameterizing the sensor via the IO-Link, you can configure the sensor via the
Teach button. Adjustable parameters:
n
Analog measurement field
n
Zero position
n
Resetting the sensor to the factory settings
INFO
You have the additional option of adjusting the mode of the Teach button via IO-Link. You have
a choice between
Xpert
(factory setting) and
Xpress
mode. For more information, see
The teach button is automatically deactivated after 5 min (the timeout can be parameterized via
IO-Link). When the teach button is pressed for longer than 12 seconds, the sensor enters oper-
ating mode without performing a parameterization.
Parameterization via the Teach button is done according to the procedure described in the fol-
lowing.
Teaching the analog measurement field
Instruction:
a) Press the teach button briefly.
ü
Green and yellow LEDs light up (teach button is active). If the LEDs do not light up, start
the sensor again.
b) Keep the teach button pressed for 4 seconds.
ü
Yellow LED blinks with 2 Hz.
c) Place the measurement object on position 1 (P1) and briefly press the teach button within
60 seconds.
ü
The min. limit of the analog measurement range has been taught in (distance at which
the min. voltage or min. current is displayed).
d) Place the measurement object on P2 and briefly press the teach button within 60 seconds.
ü
The max. limit of the analog measurement range has been taught in (distance at which
the max. voltage or max. current is displayed).
Result:
ü
Teach-in OK: Green and yellow LEDs light up briefly. Afterwards, the sensor returns to oper-
ating mode.
ü
Teach-in not OK: Green and yellow LEDs blink simultaneously with 8 Hz.