4.6.2
Indication LEDs
While the underlying functionality of the LEDs is in general well defined, it is possible to deactivate or to
invert those.
Figure 23
LED Indication - Standard-behavior in operating mode
Parameter name
Short Description
Rights
Unit / Allowed
values
LED Settings.Green Mode
Power on/short circuit
rw
On
Off
LED Settings.Yellow Mode
Connected to output 1
-
State
-
Signal close to threshold/weak signal
The weak signal can be configured by using
the quality bit (section4.7)
Default:
LED on if output is active
rw
On
Off
Inverted
If the LED mode is set
-
On,
the behaviour of the related LED is as described in Figure 23.
-
Off
, the LED is deactived except if the function Find Me is activated. (See section 3.2.2)
-
Inverted
, the LED behaviour is inverted to the definition in Figure 23.