en_BA_O200_IO-Link_V1.docx
19/34
Baumer Electric AG
15.08.2018/
Frauenfeld, Switzerland
Parameter name
Short Description
Rights
Unit / Allowed
values
Response Delay.SSC4 Time
Sets the response delay time,
Available for SSC1, SSC2, SSC3
and SSC4
rw
0 to
60’000 ms
Release Delay.SSC4 Time
Sets the release delay time,
Available for SSC1, SSC2, SSC3
and SSC4
rw
0 to 60’000 ms
Minimum Pulse Duration.SSC4 Time
Sets the response delay time,
Available for SSC1, SSC2 , SSC3
and SSC4
rw
0 to 60
’000 ms
4.3.4.2
SSC4 Behavior
By enabling autoreset, a full-featured counter being able to count lot sizes can be created without any need
of a manual reset.
Timefilters like
Response Delay
can help to optimize the timing of the execution of a subsequent actor.
Figure 21 illustrates the behavior of SSC4 using different setting. SSC4 source is hereby the switchcounter
of SSC1.
Figure 21
Behavior SSC4/Counter: Single-Point or Window, Autoreset enabled or disabled