Baumer Hübner
Technical data
|
8
V1, T1 | HMG10 & HMG10P EtherNet/IP
Operating Manual
39
8
Technical data
HMG10
Electrical Data
Voltage supply Ub
10-30 V DC
Short-circuit proof
Yes
Operating current without load
≤ 200 mA
Initializing time
≤ 500 ms after switch-on
Sensing principle
Magnetic
Fieldbus interface
EtherNet/IP
Data rate (programming interface)
100 Mbit/s
User address
HEX rotary switch in the bus terminal box or
with BOOTP/DHCP tool
Steps per turn
8192 / 13 Bit
Number of turns
65536 / 16 Bit
Incremental output
Rectangle TTL/HTL, TTL/RS422
Interference immunity
see data sheet and declaration of conformity
Interference emission
see data sheet and declaration of conformity
Programming interface
RS485 (≤ 600 m)
I
Programmable parameters
Bus system (see reference at the end of the
chapter)
Additional output (ppr number)
I
Switch off / on speed
I
Diagnostic functions
Position and parameter errors
LED status indicator
DUO LED and Link/Activity LEDs in bus termi-
nal box
4 LEDs at rear of the device
Approvals
see data sheet and declaration of conformity
Electrical data (Speed switch)
Switching accuracy
±2 % (or 1 digit)
Switching outputs
1 output
(Open-collector
II
or semiconductor relay
II
)
Output switching performance
30 V DC; ≤ 100 mA
Switching delay
≤ 20 ms
Mechanical
Dimensions (flange)
ø 105 mm
Shaft type
HMG10-B
ø 16...20 mm (blind hollow shaft)
ø 17 mm (cone shaft 1:10)
HMG10-T
ø 16...20 mm (through hollow shaft)
Flange
Torque plate, in any position throughout 360°