7
|
Disassembly
Baumer Hübner
38
Operating Manual
HMG10 & HMG10P EtherNet/IP | V1, T1
7.2
Detaching the encoder from through-hollow shaft
DANGER
Burns caused by heat
The device heats up at high torque. There is a risk of getting burned after use.
a) Avoid overheating the device.
b) Wear suitable gloves.
1
3
2
9
7
8
4
4
1
1
4
≥
ø
d
>113 mm
ø
d
5 6
Ill. 11:
Detaching the encoder from the through-hollow shaft
1
Self-locking nut M6 (ISO 10511)
2
Threaded rod M6 (variable length ≤ 210
mm)
3
Grounding strap
4
Washer B6.4 (ISO 7090)
5
Through hollow shaft
6
Torx screw M3x12 mm (ISO 7045)
7
Torque arm
8
Cheese-head screw M6x8 mm for
grounding strap (ISO 1207)
9
Washer B6.4 for grounding strap (ISO
7090)
Tool
n
1,6×8 mm
n
10 mm
n
10 mm
Instruction:
a) Loosen the Torx screw at clamping ring. Do not unscrew the screw completely.
b) Loosen the self-locking nut on the torque arm
c) Loosen the cheese-head screw at grounding strap.
d) Slide the encoder off the shaft.