MB072T2 - 11070661
Baumer_HOG11-HOG11G_T2_DE_EN_202203_MI_11070661 (22A1)
34
Technical data
10
10
Technical data
10.1
Technical data - electrical ratings
•
Voltage supply:
9...30 VDC
10)
(HTL-P, TTL - version R)
5 VDC ±5 % (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
300...5000 (as ordered)
•
Phase shift:
90° ±20°
•
Duty cycle:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output frequency:
≤120 kHz; ≤300 kHz option
•
Output signals:
K1, K2, K0 + inverted
Error output (option EMS)
•
Output stages:
HTL-P (power linedriver), TTL/RS422
(as ordered)
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approvals:
CE|UL-Zulassung / E217823, DNV approval (option)
10.2
Technical data - mechanical design
•
Size (flange):
ø105 mm
•
Shaft type:
ø12...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
•
Admitted shaft load:
≤450 N axial; ≤600 N radial
•
Protection EN 60529:
IP67
•
Operating speed:
≤6000 rpm (mechanical)
•
Operating torque typ.:
6 Ncm
•
Rotor moment of inertia:
340 gcm
2
•
Materials:
Housing: aluminium die-cast
Shaft: stainless steel
•
Operating temperature:
-40…+100 °C
-25...+100 °C (>3072 pulses per revolution)
-50...+100 °C (option heating)
Restricted in potentially explosive environments, see section 2.
•
Resistance:
IEC 60068-2-6, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27, Shock 300 g, 6 ms
•
Corrosion protection:
IEC 60068-2-52 Salt mist
complies to ambient conditions CX (C5-M)
according to ISO 12944-2
•
Explosion protection:
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
•
Connection:
Terminal box, 2x terminal box (option M)
•
Weight approx.:
1.6 kg; 1.8 kg (option M)
2.9 kg (option G); 3.3 kg (option G + option M)
10)
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution