2.  Safety precautions and operating information 

Additional information 

  The manual is a supplement to the documentation which already exists (catalogues, product information 

and installation manuals). 

  It is imperative that the manual is read prior to commissioning. 

 

Proper use 

  The encoder is a precision measuring device.  It is used exclusively for the detection of angle positions 

and rotations, and the processing and provision of the measured values as electrical output signals for 
the next device. The encoder may only be used for this purpose. 

 

Commissioning 

  The encoder may only be installed and mounted by a qualified electrician. 

  Observe the operating manual of the machine manufacturer. 

 

Safety precautions 

  Check all electrical connections before commissioning the system. 

  If installation, electrical connection or other work on the encoder and on the system are not carried out 

properly, malfunction or failure of the encoder may result. 

  The endangering of persons, damage to the system and damage to operating equipment due to the 

failure or malfunction of the encoder must be prevented with suitable safety measures. 

  The encoder may not be operated outside the specified limits (see additional documentation). 

 

Failure to observe the safety precautions can lead to malfunctions, damage and injuries! 

 

Transport and storage 

  The encoder may only be transported and stored in the original packaging. 

  Do not drop the encoder or subject it to major jolts or impacts. 

 

Assembly 

  Avoid impacts or shocks to the housing and shaft. 

  Do not torque the housing. 

  Do not produce a rigid connection between the encoder and drive shafts. 

  Do not open the encoder or modify it mechanically. 

 
The shaft, ball bearings, glass plate or electronic parts can be damaged. Safe operation is then no longer 
ensured. 

 

Electrical commissioning 

  Do not modify the encoder electrically. 

  Do not carry out wiring work while the encoder or system is energized. 

  The electrical connection may not be connected or disconnected while energized. 

  Install the entire system so that it is EMC-compliant. The installation environment and wiring affect the 

EMC of the encoder. Install the encoder and the supply lines in separate locations or at a great distance 
from wiring with a high interference level (frequency converters, contactors etc.). 

  For consumers with high interference levels, provide a separate power supply for the encoder. 

  Complete screen the encoder housing and the connection cables. 

  Connect the encoder to protective ground and use shielded cables. The cable shield must be connected 

to the screw cable terminal or plug. Connection of the protective ground at both ends, the housing via the 
mechanical attachment, and the cable shield via devices connected downstream should be aimed for. If 
problems occur with ground loops, grounding should be carried out on at least one end. 

 
Failure to observe the above can lead to malfunctions, damage and injuries! 

 

Содержание GXP8W

Страница 1: ...ngen Schwenningen Phone 49 0 7720 942 0 Fax 49 0 7720 942 900 05 11 174 02 041 3 info de baumerivo com Subject to technical and design modifications www baumer com Errors and omissions excepted Manual...

Страница 2: ...modes 5 3 1 Poll Mode 5 3 2 Change of status Mode COS 5 3 3 Cyclic Mode 5 4 Encoder operating parameters 5 5 Object model 6 6 E A Entities Assembly 7 7 Encoder configuration 8 8 Encoder Position Objec...

Страница 3: ...ect or indirect damages resulting from the use of the present information At any time we should be pleased receiving your comments and proposals for further improvement of the present document 1 Intro...

Страница 4: ...nd storage The encoder may only be transported and stored in the original packaging Do not drop the encoder or subject it to major jolts or impacts Assembly Avoid impacts or shocks to the housing and...

Страница 5: ...e 1 65535 ms 4 Encoder operating parameters Significance of operating parameters Parameter Significance Value range Default setting decimal hex Bit decimal Sense of rotation Behaviour of the output co...

Страница 6: ...es and the number of entities available in each class object class number of entities 01h Identity 1 02h Message Router 1 03h DeviceNet 1 05h Connection 1 explicit 2 E A 04h Assembly 2 0Fh Parameter 1...

Страница 7: ...ing 1 The encoder provides following data which are input data from the Master s point of view entity type name 1 input position value 2 input position value warnflag alarmflag E A Assembly data attri...

Страница 8: ...Steps per revolution 7 6 Total resolution in steps 8 7 Measurement steps not used 9 8 Preset value 10 9 Position value 12 10 Operating status 80 11 Singleturn resolution 81 12 Number of revolutions 8...

Страница 9: ...lution see operating parameter 8 read write Total resolution UDINT Number of desired steps exceeding the measurement range see operating parameter 9 read Reserved UDINT reserved 0 10 read write Preset...

Страница 10: ...parameters 82 read Number of revolutions UINT Internal number of revolutions see operating parameters 83 read Alarm signals UINT Malfunction may lead to wrong encoder position Bit 0 0 no position err...

Страница 11: ...attribute 88 is also set with every warning Offset Attribute 91 comprises the parameter offset value The offset value is calculated within the preset function and will shift the position value by the...

Страница 12: ...hanical backlash Pay attention to the admissible axial or radial shaft loads For suitable connecting devices see under accessories Tighten the fastening screws 9 2 Electrical connection 9 2 1 Setting...

Страница 13: ...our Status Significance off not connected No power supply Dupl MAC ID check not terminated No power supply Green flashing Device is active and online No connections established The device is operating...

Отзывы: