Baumer_BiSS-C_MA_EN_V1 00.docx
6/10
www.baumer.com
25.08.2016
3 Introduction
This specification describes a serial interface protocol for isochronous, fast and safe exporting of sensor data
and simultaneous accessing of the slave registers.
In the point-to-point configuration, only one device with one slave (sensor) is operated on the master. The
BiSS interface is hardware-compatible to the SSI interface in the point-to-point configuration and only
requires two unidirectional differential lines.
Figure 1