MB132 - 11055745
Baumer_OG9_II_DE-EN (19A2)
22
Technical data
9
9
Technical data
9.1
Technical data - electrical ratings
•
Voltage supply:
9...30 VDC (HTL-P, TTL - version R ≥95 pulses)
9...26 VDC (TTL - version R <95 pulses)
5 VDC ± 5 % (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
1...5000 (as ordered)
•
Phase shift:
90° ±20°
•
Duty cycle:
40...60%
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output frequency:
≤120 kHz, ≤300 kHz option
•
Output signals:
K1, K2, K0 + inverted
•
Output stages:
HTL-P (power linedriver), TTL/RS422
(as ordered)
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approvals:
CE, UL approval / E256710
9.2
Technical data - mechanical design
•
Size (flange):
ø115 mm
•
Shaft type:
ø11 mm solid shaft
•
Admitted shaft load:
≤250 N axial, ≤350 N radial
•
Flange:
EURO flange B10
•
Protection DIN EN 60529:
IP55
•
Operating speed:
≤12000 rpm (mechanical)
•
Operating torque typ.:
1 Ncm
•
Rotor moment of inertia:
280 gcm
2
•
Materials:
Housing: aluminium die-cast
Shaft: stainless steel
•
Operating temperature:
-30…+100 °C
-25…+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
•
Resistance:
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
•
Corrosion protection:
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
•
Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
•
Connection:
Terminal box
•
Weight approx.:
980 g