Instructions for use, installation and connection
34
Electrical connections
Open the connection box using
the screwdriver, as shown by the
drawing on the cover.
Connection to the mains power can be
done only by the authorized service
center or by qualified personnel!
Wrong connection may damage the
parts of appliance and render your
warranty viod!
Connecting voltage of the user’s
installation (230 V against N) must be
verified by qualified electrician using the
appropriate tester.
Connector bridges must be positioned
in accordance with the installation
connection!
x
Prior connecting the appliance, check
whether the voltage of the rating plate
corresponds to the actual voltage of
home installation.
x
Length of the power lead must be at least
1.5 m so that the appliance can be
connected to power before pushing it
against the wall.
x
Length of the earthing lead must be
longer than the others, so that it is
strained later than the tension power
leads in case of accidental pullout from
the socket.
Procedure
x
Using the screwdriver open the
connection box cover at the back of the
appliance. You can do so by releasing
two catches, as shown on the connection
box cover.
x
Power cable must be guided through the
relief device, protecting it from pulling out.
If the relief device has not been fixed yet,
fix it in such way to hook the power cable
to the device housing at one end.
x
Now connect the power cable in
accordance to
one
of the options shown
on the figure. In case of different
installation voltages, the connection
bridges should be rearranged
accordingly!
x
Tighten the relief device and close the
connection box cover.
NOTE:
In some connection boxes the connector
bridges are placed between contacts 4
and 5, and in the others they are stored
at a designated place within the box.
These boxes have the connection screws
already in open position so they need not
be unscrewed. During the tightening
procedure you will hear a faint “click”,
meaning that the tightening screw should
be fastened tightly all the way.
Colored power leads
L1, L2, L3 = exterior power leads under
tension. Usual colors are black, black,
brown.
N = neutral lead
Usual color is blue.
Watch for the correct N-connection!
PE = earthing (protective lead)
Lead color is green-yellow.