Baumatic BECW600 Скачать руководство пользователя страница 25

 

25 

8)

 

Insert  rawl  plugs  into  all  of  the  holes  that  you  have  drilled. 
IMPORTANT: Rawl plugs are provided to secure the hood to 

most  types  of  walls  and  ceilings.  However  a  qualified 
technician  must  verify  the  suitability  of  the  materials,  in 

accordance  with  the  type  of  wall  and  ceiling.  The  wall  and 
ceiling must be strong enough to take the weight of the hood.
  

 

9)

 

Fix  the  wall  bracket  to  the  wall  using  the  three  4  mm  x  30 
mm screws supplied. These screws MUST BE fully tightened. 

 

10)

 

For  the  sloped  cooker  hood  models  only,  additionally  you 

should screw four 4 mm x 30 mm screws into the anchoring 
holes that you drilled out in step 7. These screws should not 

be  fully  tightened  at  this  stage  and  10  mm  left  protruding 
from the wall. 

 

11)

 

Hang  the  hood  onto  the  wall  bracket,  ensuring  that  it 

locates securely into the slots in the rear of the cooker hood 
body. 

 

12)

 

For the sloped cooker hood models only, the hood needs to 

be located onto the protruding screws that you fitted in step 

10. These screws MUST NOW BE fully tightened. 

 

Connecting to external ducting 
 

13)

 

If you wish to fit a 150 mm ducting hose to the appliance, 

then you may connect this directly to the circular opening on 

the  top  of  the  cooker  hood.  If  you  wish  to  fit  a  125  mm 
ducting  hose  to  the  appliance,  then  you  must  fit  the  150  to 

125 mm reducer. 

 

14)

 

Ensure  that  the  circular  non  return  flap  which  sits  in  the 

outlet  at  the  top  of  the  cooker  hood  is  in  position  before 

connecting the ducting hose. 

 
15)

 

Fit the ducting hose to the appliance (please note that the 

ducting hose is not supplied). 

 

16)

 

 The other end of the ducting hose should be connected to 

a  discharge  outlet  that  is  suitable  for  cooking  vapours.  It 

should have a cross section of at least 150 cm². 

 

17)

 

The  maximum  distance  between  the  coupling  and  your 

discharge  outlet  should  be  3  metres,  with  one  90  degree 

bend.  For  each  additional  90  degree  bend,  the  maximum 
distance is reduced by a further metre. 

 
 

Содержание BECW600

Страница 1: ...BECW600 900SS BESW601BGL WGL BESW901BGL WGL BESW902BGL Chimney Hood...

Страница 2: ...Instruction Manual contains important information including safety installation points which will enable you to get the most out of your appliance Please keep it in a safe place so that it is easily...

Страница 3: ...hood 16 Cleaning 16 The grease filters 16 Maintenance 17 20 Removing and cleaning the grease filters 17 Changing a light bulb 18 19 Fitting the carbon filter 19 20 Installation 20 28 Electrical connec...

Страница 4: ...old appliance switch off and disconnect it from the power supply Cut off and render any plug useless Cut the cable off directly behind the appliance to prevent misuse This should be undertaken by a co...

Страница 5: ...st be in accordance with the Gas Safety Codes of Practice BS 6172 BS 5440 BS 6891 Natural Gas and BS 5482 LP Gas 1994 the Gas Safety Installation Use Regulations the Building Regulations issued by the...

Страница 6: ...ypes of flue or appliances are fitted ensure that there is an adequate supply of air in the room o When the hood is being used in its extractor function ensure that the ducting is fire retardant and t...

Страница 7: ...g used for any other purpose o Do not install above a cooker with a high level grill o Never leave frying pans unattended during use as overheated fats and oils might catch fire o The lights on this a...

Страница 8: ...Energy efficiency class A Extraction or recirculation 150 mm with 120 mm adapter Optional extras Carbon filter for recirculation 1 x pair S4 DK5 1 Metre length Ducting Kit 125 mm diameter DK10 3 Metre...

Страница 9: ...class A Extraction or recirculation 150 mm with 120 mm adapter Optional extras Carbon filter for recirculation 1 x pair S4 DK5 1 Metre length Ducting Kit 125 mm diameter DK10 3 Metre length Ducting Ki...

Страница 10: ...r recirculation 150 mm with 120 mm adapter Optional extras Carbon filter for recirculation 1 x pair S4 CQ5SS Stainless steel chimney sections DK5 1 Metre length Ducting Kit 125 mm diameter DK10 3 Metr...

Страница 11: ...r recirculation 150 mm with 120 mm adapter Optional extras Carbon filter for recirculation 1 x pair S4 CQ5SS Stainless steel chimney sections DK5 1 Metre length Ducting Kit 125 mm diameter DK10 3 Metr...

Страница 12: ...recirculation 150 mm with 120 mm adapter Optional extras Carbon filter for recirculation 1 x pair S4 CQ5SS Stainless steel chimney sections DK5 1 Metre length Ducting Kit 125 mm diameter DK10 3 Metre...

Страница 13: ...enter stand by mode automatically o When you connect the cooker hood to the power supply the cleaning reminder symbol will appear on the LCD display This can be cleared by pressing the light button on...

Страница 14: ...cooker hood motor on you should press the plus button and the hood will start to operate on low speed The motor has 3 speeds which are low medium and high plus boost o Pressing the plus button once wi...

Страница 15: ...t lighting source for your kitchen The cut off timer o You can program your cooker hood to switch off automatically after a set time o To set a cut off time switch the hood on and select the required...

Страница 16: ...lter A build up of grease could cause a fire hazard o Never attempt to clean the area above the grease filter s The grease filters o Your cooker hood includes grease filters which help to absorb greas...

Страница 17: ...ram above o Soak the grease filters in hot water and washing up liquid for at least 3 minutes Then use a soft brush to loosen any grease deposits that have formed o Rinse the grease filters off thorou...

Страница 18: ...Using a screwdriver gently prise the edge of the light unit out of the fixture as shown in the picture below Please note that it may be easier to use two screwdrivers o Once the light unit has been re...

Страница 19: ...ood has been reconnected to the power supply before contacting the Customer Care Department Fitting the carbon filters If the appliance is being used to be used in recirculation mode then it is necess...

Страница 20: ...and the regular operation of the electric system Electrical connection YOUR COOKER HOOD IS INTENDED FOR FITTED AND PERMANENT INSTALLATION o The cooker hood s power cable must be fitted upstream from...

Страница 21: ...ce to connect a ducting hose to the outside o Carry out all necessary masonry work prior to the fitting of the cooker hood o Ensure that all electrical connections are carried out by a suitably qualif...

Страница 22: ...WILL HAVE TO DECIDE BEFORE INSTALLING YOUR COOKER HOOD WHETHER TO USE IT IN EXTRACTION MODE OR RECIRCULATION MODE What is the difference between extraction and recirculation modes In extraction mode...

Страница 23: ...are observed between the highest point on the hob top including the burners and the bottom of the cooker hood Electric appliances 700 mm Gas appliances 700 mm Coal oil cookers 800 mm IMPORTANT DO NOT...

Страница 24: ...oped cooker hood models only BESW601 BESW901 and BESW902 you must also mark out the position of the anchoring points on the rear of the appliance 5 Remove the cooker hood from the wall and place it on...

Страница 25: ...r the sloped cooker hood models only the hood needs to be located onto the protruding screws that you fitted in step 10 These screws MUST NOW BE fully tightened Connecting to external ducting 13 If yo...

Страница 26: ...he gap at the top of the cooker hood body with the upper chimney section sitting inside of it 19 Place the flat bracket into the keyhole slots at the top of the lower chimney section Mark out the posi...

Страница 27: ...he top of the lower chimney section as shown in the diagram on page 25 28 Raise the upper chimney section until it reaches the ceiling 29 Secure the upper chimney section to the L shaped bracket using...

Страница 28: ...peed control is set correctly My cooker hood is not working effectively o The fan speed is not set high enough o The grease filters are dirty and require cleaning o The kitchen is not well ventilated...

Страница 29: ...gineer to perform any necessary repair If your appliance is installed in such a way that an engineer is concerned that damage will be caused to the appliance or your kitchen then they will not complet...

Страница 30: ...tical A weighted sound power emissions at maximum speed available in normal use 64 The air bone acoustical A weighted sound power at intensive or boost setting The power consumption in off mode Po The...

Страница 31: ...weighted sound power emissions at maximum speed available in normal use 64 The air bone acoustical A weighted sound power at intensive or boost setting The power consumption in off mode Po The power...

Страница 32: ...al A weighted sound power emissions at maximum speed available in normal use 70 The air bone acoustical A weighted sound power at intensive or boost setting The power consumption in off mode Po 0 6 Th...

Страница 33: ...ustical A weighted sound power emissions at maximum speed available in normal use 70 The air bone acoustical A weighted sound power at intensive or boost setting The power consumption in off mode Po 0...

Страница 34: ...34...

Страница 35: ...35 Customer Care Telephone 0844 692 3605 Spare Part Telephone 0844 692 3606...

Страница 36: ...36 Part of the Hoover Group 11 Beacontree Plaza Gillette Way Reading RG2 0BS www baumatic co uk...

Отзывы: