32
Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o
Remove the pan supports, burner cap and burner rings.
o
Unscrew the injector and replace it with the required injector for
the new gas supply according to the table below.
Burner Type
Gas Type Pressure
Mbar
Injector
Marking
(1/100mm)
Power
(Kw)
Max Min
Natural
Gas
20 72
Auxiliary (Small)
Liquid Gas 28..30/37
50
1 0.3
Natural
Gas
20 97
Semi Rapid
(Medium)
Liquid Gas 28..30/37
65
1.75 0.6
Natural
Gas
20 115
Rapid (Large)
Liquid Gas 28..30/37
85
3 1
o
When all four jets have been replaced, reassemble all the
burners carefully, taking particular care to make sure that the
burners and burner caps are aligned properly.
o
After changing the injectors YOU MUST change the minimum
flow rate.