5

. Push the light button; the indicating light 4 on, and the two lighting lamps 

will come on. Push it again and the lamps will turn off, with every push the 

buzzer will buzz one time.   

 

 

 

 

 

 

 IMPORTANT:  

Before cleaning, always ensure that you have 

switched your cooker hood OFF at the power switch, set at 

the wall from the cable: 

 

Cleaning 

 

 

Clean the external parts with 
mild liquid detergents on a 

damp cloth.   

 

 

Never use abrasive powder, 

corrosive solvents or brushes. 

 

 

Never insert pointed objects 
into the motor‟s protective grid. 

 

 

Only clean the control panel 

and filter grill with a damp 

cloth and delicate detergents. 

 

 

Be sure to replace the 
carbon filters at the 

recommended intervals.  
Build up could cause a 
fire hazard. 

 

 

Never take out the 

grease filters and 
attempt to clean the 

space above where they 

are set

________________________________________________

Anti-Grease Grille  
 

 

Your cooker hood includes an 

anti-grease grille

 which helps 

absorb vapour-suspended grease particles to protect your 
kitchen & furniture from greasy residues.  

 

 

The metal grille may become inflammable if it becomes 
saturated with greasy residue.   

 

 
 

Cleaning your Cooker Hood: 

 

Содержание BAH9009G

Страница 1: ...d in Stainless Steel NOTE This User Instruction Manual contains important information including safety installation points which will enable you to get the most out of your appliance Please keep it in...

Страница 2: ...E ENVIRONMENT 5 USING YOUR COOKER HOOD 6 MAINTAINING AND CLEANING YOUR COOKER HOOD 7 9 INSTALLATION INSTRUCTIONS 10 17 CARBON FILTER 10 ELECTRICAL CONNECTION 11 INSTALLING THE COOKER HOOD 12 13 INSTAL...

Страница 3: ...nsure that your Cooker Hood has been installed properly DIMENSIONS Width canopy 900 mm Depth canopy 600 mm Height adjustable 690 1170 mm Dimensions of Pipe Section 270mm X 285mm Your stainless steel C...

Страница 4: ...ances are being observed between the cooker top and the bottom of the cooker hood Electric cookers 600 mm Gas cookers 600mm NOTE DO NOT SET YOUR COOKER HOOD LESS THAN 600mm ABOVE YOUR COOKER o When in...

Страница 5: ...mber that when in extraction mode your cooker hood is removing air from your room Ensure that proper ventilation measures are being observed Note that it removes odours from your room not steam o Warn...

Страница 6: ...ote Before discarding an old appliance switch off and disconnect it from the power supply Cut off and render any plug useless Cut the cable off directly behind the appliance to prevent misuse This sho...

Страница 7: ...at least as soon as you start cooking 1 Turn on the power the buzzer will buzz five times The sound shows that the appliance is powered 2 Push the low button the indicating light 1 on the buzzer will...

Страница 8: ...pointed objects into the motor s protective grid Only clean the control panel and filter grill with a damp cloth and delicate detergents Be sure to replace the carbon filters at the recommended interv...

Страница 9: ...own on it Undo the side catches You can now clean the anti grease filter grilles Soak them for about one hour in hot water with a grease loosening detergent then rinse off thoroughly with hot water Re...

Страница 10: ...ave switched it off so that it s in the 0 position Remove the metal anti grease filters see Figure 2 below and find the old bulb located in the light fixture up inside the exposed canopy Change the ha...

Страница 11: ...uses CARBON FILTERS to purify the air for the air recirculation function You will find two filters that will attach to both sides of the fan motor please see figures at bottom of page The active carb...

Страница 12: ...the electric system ______________________________________________ ELECTRICAL CONNECTION Y Yo ou ur r c co oo ok ke er r h ho oo od d i is s i in nt te en nd de ed d f fo or r f fi it tt te ed d w wi...

Страница 13: ...big flat screws will be used to fix the hanging board on the ceiling and then 8 M4 10 screws and a M4 nut with gasket will be used to connect the angle iron into the hanging board see pic 1 After calc...

Страница 14: ...13 8 Put the extendable pipe on the outlet after ensuring everything is ok put down the hook and the external chimney then the installation is complete see pic 9 Installation Instructions...

Страница 15: ...ding make a hole in the wall that is large enough to fit a wind and rain proof shutter with a cross section of at least 150 cm and connect this to the outlet union of the unit by means of a pipe _____...

Страница 16: ...o work as an air purifier in the event that there is no provision for an external air discharge duct In this case air is recycled through the union N Fig 1 above When using the unit as an air purifier...

Страница 17: ...s not set high enough The grease filter is dirty The kitchen is not ventilated well enough If the hood is set for recirculation check that the carbon filters have not expired If the hood is set for ex...

Страница 18: ...enewable insurance scheme for labour is available should you wish to extend the warranty period Should any person other than a qualified techician interfere with the appliance the policy is negated an...

Страница 19: ...rs baskets trays shelves burner bases burner caps decals corrosion rubber seals refrigeration system blockage In the course of the work carried out it may be necessary to remove the appliance from its...