o
IMPORTANT:
The minimum flow adjustment process must
be completed before the appliance is next used.
Minimum flow adjustment for hob gas taps.
All work must be carried out by a CORGI registered
engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o
Switch the burner
on and set the
knob at the
minimum
position.
o
Remove the knob
from the tap and
place a small
bladed
screwdriver in the
centre of the tap
shaft.
o
Unscrew the adjusting screw, in order to increase the gas flow
or tighten the adjusting screw to decrease the gas flow.
o
The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
o
For butane/propane gas, the adjusting screw must be tightly
screwed in.
o
Refit the control knob.
o
Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. If it does then remove
the control knob and make further adjustments to the gas
flow, testing it again once the adjustment has been made.
o
Repeat this process for each one of the gas taps.