10
•
Disconnect the gas pipe from the gas tap, disassemble from the gas rail by removing the
fixing screws.
•
When fitting a new tap, ensure that a new gasket is used.
•
Re-connect the gas tap, check for gas soundness and reassemble the hob.
TECHNICAL DATA
ELECTRICAL DETAILS
Rated Voltage
230V ac 50Hz
Supply Connection
13A (double pole switched fused outlet with 3mm contact gap)
Power Input
0.008 to 0.02kW (depending on model)
Mains supply lead
3 x 0.75mm2 Type RR-F
<
HAR
>
marked
GAS DETAILS
Connection
Rp ½ (ISO R7)
Type
Natural Gas (20.9 mbar) – alternative LPG G30 (28-30 mbar)
[Town Gas G110 – 120 (8 mbar) to order]
BURNER TYPES AND POWER INPUTS : kW
Model
Large
Medium
Small
Wok
Fish
Total
Max / Min
Max / Min
Max / Min
Max / Min
Max / Min
KW
AS9.1AL VALV
3.0 / 0.7
1.75 / 0.4
1.0 / 0.35
3.5/1.7
-
11.0
B40
3.0 / 0.9
1.75 / 0.4
-
3.8 / 1.75
-
8.55
B72TCBL
-
1.75 / 0.4
1.0 / 0.35
3.5/1.7
-
11.0
B77TCBL
3.0 / 0.7
1.75 / 0.4
1.0 / 0.35
3.5/1.7
-
11.0
B78
3.0 / 0.7
1.75 / 0.4
1.0 / 0.35
3.5/1.7
-
11.0
JET SIZING CONVERSION TABLE: NATURAL GAS / LPG
Model Large
Medium
Small
Wok
Fish
NG / LPG
NG / LPG
NG / LPG
NG / LPG
NG / LPG
AS9.1AL VALV
1.15 / 0.85
0.97 / 0.65
0.72 / 0.50
1.35/0.95
-
B40
1.15 / 0.85
0.97 / 0.65
-
1.35 / 0.98
-
B72TCBL
-
0.97 / 0.65
0.72 / 0.50
1.35/0.95
-
B77TCBL
1.15 / 0.85
0.97 / 0.65
0.72 / 0.50
1.35/0.95
-
B78
1.15 / 0.85
0.97 / 0.65
0.72 / 0.50
1.35/0.95
-