INSTALLATION INSTRUCTIONS 

VENTILATION OF ROOMS 

 
The room in which this appliance is installed must be well ventilated by natural or mechanical 
means, or a combination of both to ensure correct combustion and the removal of spent air. 
The minimum quantity of air for combustion will depend on the room volume, number of 
appliances and their total power rating. 
The power rating of your appliance can be found by reference to the Rating Plate.                                                           
 
Note: The actual ventilation requirements must be determined by reference to the Statutory 
Regulations in force.   
 
 

GAS CONNECTION 

 
The gas supply must be connected by use of the ½ BSP Elbow, Seal and copper pipe and an 
isolation tap fitted in an easily accessible position. 
The appliance as supplied is for use with Natural Gas, if it is to be adapted for LPG proceed as 
follows: 

• 

Isolate the appliance from the electricity and gas supplies. 

• 

Remove the pan supports and burner assemblies. 

• 

Replace the injectors with the alternative type supplied. 

• 

Use the appropriate thread sealant and check for gas soundness. 

• 

Affix the self-adhesive label to the Rating Plate to amend the Gas Category. 

 
 
Fig 

      Fig 

 
 
 
 
 
 
 
 
 
 
 

GAS FLOW ADJUSTMENT 

 

 

 
In order to adjust the minimum gas flow proceed as follows: 

• 

Ignite the burner and turn down to the minimum setting. 

• 

Remove the control knob from the gas tap. 

• 

Adjust the flow either clockwise to decrease or anti-clockwise to increase the flame. Use a 
screwdriver inserted down the gas tap rod or via the screw head adjacent to the rod for 
models fitted with a Flame Supervision Device.  

• 

Check that the flame is 3- 4 mm in length, bluish in colour, stable and noiseless, and does not 
extinguish when changing from maximum to minimum flow. 

• 

Replace the control knob and check that all components have been reassembled correctly.   

 10 

Содержание AS4.1

Страница 1: ...GAS HOBS USER AND INSTALLATION INSTRUCTIONS...

Страница 2: ...r future reference please record the following information which can be found on the Rating Plate and the date of purchase which can be found in the invoice Model Number Serial Number Date of Purchase...

Страница 3: ...NTS General Information page 4 Warning and Safety Instructions page 5 Instructions for Use pages 6 7 Instructions for Installation Pages 8 12 Technical Data Pages 12 13 Conditions of Guarantee Back co...

Страница 4: ...agreement of Baumatic Ltd would invalidate any warrantee or liability claim Your new appliance is guaranteed against electrical or mechanical defects subject to certain exclusions noted in Baumatic Lt...

Страница 5: ...t size for the heating area to be used never smaller Do not allow electrical fittings or cables to be in contact with hot areas of the appliance Do not use the appliance for space heating or to dry cl...

Страница 6: ...an be released 2 Manual Ignition After pressing in and turning the appropriate knob anti clockwise to the large flame symbol press the ignition button located on the control panel The ignition spark w...

Страница 7: ...l burners are variable between full and low positions WARNING Do not use commercial simmering aids as these can create excessive heat which can damage the appliance CLEANING THE APPLIANCE Always allow...

Страница 8: ...tallation of Flues and Ventilation for Gas Appliances Baumatic Ltd Installation Instructions POSITIONING THE APPLIANCE This appliance is classified as Class 3 and therefore is to be built into a kitch...

Страница 9: ...t leave a gap in the sealing agent or overlap the thickness NOTE do not use any Silicone based sealant as this can damage the worktop surface if repairs are required 4 Insert the appliance into the ap...

Страница 10: ...for LPG proceed as follows Isolate the appliance from the electricity and gas supplies Remove the pan supports and burner assemblies Replace the injectors with the alternative type supplied Use the a...

Страница 11: ...Green and Yellow must be connected to the terminal marked E or the earth symbol or coloured green and yellow The wire coloured Blue must be connected to the terminal marked N or coloured blue or Blac...

Страница 12: ...h high temperature grease reassemble into position and rotate a few times Remove the cone again and remove any excess grease making sure that the gas ducts are not obstructed with grease Carefully rea...

Страница 13: ...3 0 0 7 1 75 0 4 1 0 0 35 7 5 AS5 1 3 0 0 7 1 75 0 4 1 0 0 35 10 5 B70 3 0 0 7 1 75 0 4 1 0 0 35 7 5 JET SIZING CONVERSION TABLE NATURAL GAS LPG Model Large Medium Small Wok Fish NG LPG NG LPG NG LPG...

Страница 14: ...ranty period This guarantee applies to UK mainland and Northern Ireland only THIS GUARANTEE DOES NOT COVER Any damage caused by transit misuse or neglect Cosmetic and perishable parts plugs fuses ligh...

Отзывы: