5. Route hoses along boom and connect to
excavator hydraulic system. Connect case
drain hose to excavator reservoir.
Other installed attachments may interfere
with drop saw operation and may need to be
removed. Routing of the hoses will depend on
the excavator and other installed attachments.
Baumalight does not provide these hoses
and they are not covered by the Baumalight
warranty�
NOTICE
Prevent equipment damage�
Route hydraulic hoses away from pinch
points�
During initial startup, carefully move
drop saw and boom to all positions to
verify hoses will not be damaged�
4�1�2 Excavator Adapter
1. Install excavator adapter (A) on either side of
machine mounting bracket (B) as shown.
2. Install and tighten mounting hardware.
Tightening the mounting hardware will pull the
flanges into place.
4�2 Pre-Operation Check List
Verify that drop saw is properly attached to
excavator.
Verify that hydraulic hoses properly connected.
Check for entangled material on blade.
Verify all guards, doors and covers are installed
and secured.
Verify cutting teeth are in good condition and are
tight.
4�3 Machine Components
Dashed line indicates item hidden from view unless
cover is removed.
A. Cutting Teeth
B. Blade
C. Blade Guard
D. Hydraulic Motor
E. Hydraulic Hose Holder
F. Ripper Teeth
G. Excavator Adapter
A
B
C
D
E
F
G
11