Operating manual
BAUER Submersible Motor Pump
/ Version X-2010
17
FAULT DESCRIPTION
Fault
Cause
Remedy
The pump does not deliver
Impeller blocked
Remove foreign object
Cutter bell blocked
Remove foreign object
Excessive difference in elevation
between pump and distributing
device.
Reduce difference in elevation.
Wrong direction of rotation.
Reverse direction of rotation.
Excessive solids content.
Add water.
The discharge capacity drops.
Excessive counter pressure.
Remove foreign object.
Excessive solids content.
Add water.
Red pushbutton lights up.
Motor protection has switched off
the motor.
Eliminate the fault.
In manual mode the red pushbutton
goes out.
In level and intermittent operation
turn the mode selector to “0”, then
the red pushbutton goes out and
the alarm horn stops