COMPACTCLASSIC AHD
QUICKSTART
hardware version
1.9
software version:
V8.6 / V3.6
4 / 4
Configuration Central Call Button and door opening
•
Open the web interface of the SIP Module via a web browser via IP address.
•
Navigate to the [Setup] (password: 1234).
o
Select [Centrall Call Module]: Yes
•
Navigate to [Call destinations] (password: 1234).
•
Enter the target for the Central Call Button identical to [Switchboard call]:
o
Name: (a name must be entered)
o
Number: (destination number or IP address for direct IP connection)
o
DTMF code: (code to trigger the door relay e. g. „0 - - -“)
o
Incoming: (response to incoming call from this number)
•
Confirm your entries with [Save] (the SIP Module will restart).
Camera
•
IP Address:
192.168.1.220
•
Netmask:
255.255.0.0
•
Username:
admin
•
Password:
1234
Setting the IP address
•
Open the web interface of the IP camera in a web browser via IP address.
o
Default IP address: 192.168.1.220
•
Navigate to the [Configuration] (username: admin, password: 1234).
•
Go to the menu [General]
•
Enter your IPv4 address configuration - Ethernet:
o
IP address
o
Subnet mask
o
Gateway
•
Confirm your entries with [Save].
Display camera image or video stream
You have the following options to access the camera directly.
•
To display individual JPG pictures, use the following URL:
o
http://*username*:*password*@*Camera-IP*/jpg/image.jpg
o
With factory settings e. g.: http://admin:[email protected]/jpg/image.jpg
•
To display a Motion-JPEG stream, use the following URL:
o
http://*username*:*password*@*Camera-IP*/mjpg/video.mjpg
o
With factory settings e. g.: http://admin:[email protected]/mjpg/video.mjpg