background image

                                                              BD-PON-P2 
                                                                    Power Meter 

                                     

                                 

Quick Guide

 

Specification 

Calibrated wavelength 

1310nm(Burst) 

1310nm(CW) 

        1490(nm) 

        1550(nm) 

Sensor type 

InGaAS 

linearity 

 

±

0.2dB@1550nm

-40dBm 

Isolation 

1490nm wave band>40dB 
1550nm wave band>40dB 

1310nmwave 

band>40dB 

1550nmwave 

band>30dB 

1310nmwave 

band>40dB 

1490nm wave 

band>30dB 

Mearsuring Range(dBm)  -30dBm~+16dBm  -40dBm~+16dBm 

-50dBm~+16dBm 

-50dBm~+23dBm 

Insertion Loss(dB) 

1.5 

Spectral Width(nm) 

1260~1360 

1480~1500 

1539~1565 

Accuracy(dB) 

0.5dB

±

1nW@1550nm 

Threshold 

10sets

set by upper-computer 

Data stroage 

900 sets 

Working Temp 

-10

°

C    ~    +50

°

Humidity 

0% ~ 95%RH 

Adapter 

SC/PC

ST/PC

FC/PC customizable

 

Communicating port 

USB port 

Power Supply 

2

*AAA battery 

External power 

AC adapter DC6V/1A

optional

 

Dimension 

L*W*H 170mm*76mm*45mm 

Weight 

Approximate 400g 

 