background image

 
 

       

1550nm external modulated optical transmitter operating manual

 

 

Website: www.baudcom.com.cn    Tel

+86-21-37709251    Email: [email protected]     

- 22 -

 

There are 3 sub-interfaces

1.

 

About1550

 interface: Mainly described the basic information of the equipment. 

2.

 

Disp Paraments

 interface: Mainly described the display menu of the equipment. 

3.

 

Set Paraments

 interface: Change the device parameters in this interface. 

 
Click 

Set Paraments

 to enter 

Set Paraments

 interface as follows: 

 

The Item and Items columns list the parameters that can be changed, the Current 

column lists the present parameter values, the New column can select or type the new 
parameter values, and the Update column can update the parameters. 

The steps to change the parameters: find the item in the Item column, select the 

new parameter values in the New column, and click the corresponding Update button 
to update the parameters. 

The change steps in the Items are the same, but finally need to click the Restart 

Device button to take effect. 

Содержание BD-5800H

Страница 1: ...Shanghai Baudcom Communication Device Co LTD Website www baudcom com cn Tel 86 21 37709251 Email info baudcom com cn Model BD 5800H 1550nm External Modulated Optical Transmitter Operating Manual...

Страница 2: ...1 220V Power Module 8 3 3 2 48V Power Module 8 3 4 Menu Operation 9 3 4 1 Main Menu 9 3 4 2 Display Menu 10 3 4 3 Set Menu 11 3 4 4 Alarm Menu 12 3 4 5 AGC Mode 12 3 4 6 MGC Mode 12 3 4 7 Frequency Ad...

Страница 3: ...om cn Tel 86 21 37709251 Email info baudcom com cn 2 5 5 WEB Network Management 21 6 Maintenance and Troubleshooting 23 6 1 Cleaning Fiber Optic Connectors 23 6 1 1 Cleaning Patch Cord or Pigtail Fibe...

Страница 4: ...do in the event of problems 1 2 Product Description This optical transmitter is a 1550nm DFB laser external modulated transmitter It is specially developed for the CATV signal that satisfies HFC netw...

Страница 5: ...es The threshold value can be set up to 19dBm The optical modulator has a two way optical signal output Parts of that signal are routed to an InGaAs photodiode This detection of the optical signal has...

Страница 6: ...justment Range GHz 50GHz Optical Power dBm 2 5 2 7 2 8 2 9 2 10 SBS Threshold Value dBm 13 19 Continuously adjustable Laser Linewidth MHz 0 3 2 2 Model Test Indicators Test Model C42 D59 D84 D84 Chann...

Страница 7: ...z input noise current density EDFA with 5dB noise figure RF input level at 80 dB V TV channel 2 4 Technical Data Sheet Item Unit Technical Parameters RF range MHz 47 1003 RF flatness dB 0 75 RF return...

Страница 8: ...UP key 8 DOWN key 9 Enter key 10 RF input port or on the rear panel optional 11 20dB RF input test port 3 1 1 Indicator Description Power indicator One power supply LED yellow Two power supplies LED...

Страница 9: ...input port or on the front panel optional 5 RS232 interface 6 LAN interface 7 Optical output interface A or on the front panel optional 8 Optical output interface B or on the front panel optional 3 3...

Страница 10: ...www baudcom com cn Tel 86 21 37709251 Email info baudcom com cn 9 3 4 Menu Operation 3 4 1 Main Menu Displayed parameters Comments Boot display 1 Disp Parameters Menu one Display parameters 2 Set Par...

Страница 11: ...12V Read 12V monitor voltage RF CSO CSO monitor voltage 12V Read 12V monitor voltage RF Source The current RF signal source LASER Laser status Laser Cooling Cooling current SBS Module Temp SBS module...

Страница 12: ...and AGC two modes selectable Set AGC Set MGC Set RF adjusted value Adjustable range 0 15dB with MGC mode Adjustable range 3 3dB with AGC mode Set SBS Suppression Set SBS value Range 13 19dBm 0 5dB st...

Страница 13: ...nd also the standard operation The optical transmitter will automatically adjust to the optimal gain while the input level is in the working range see the technical data sheet And the specified OMI rm...

Страница 14: ...r unit inspect the shipping container and equipment for damage Save the shipping material for future use If the container or the equipment is damaged notify both the freight carrier and us CAUTION To...

Страница 15: ...t F connector type according to the ordering information then screw on the matched RF cable 4 3 3 Connecting the Optical Fiber Cables It has two output optical connectors DANGER The fiber carries invi...

Страница 16: ...Ethernet port on the rear panel 4 3 5 Connecting Power The is available in an AC power model or DC power model After mounting the equipment in a rack follow the power connection procedure below for th...

Страница 17: ...definitions as follow 1 No Connect 2 TX 3 RX 4 No Connect 5 GND 6 No Connect 7 No Connect 8 No Connect 9 No Connect The serial communication uses the standard NRZ form 1 starts bit 8 data bits 1 stop...

Страница 18: ...e of serial port As follows Change the serial port configuration to 38400 baud rate 8 data bits no parity bit 1 stop bit no data flow control press the OK button you have set up the Windows serial por...

Страница 19: ...rating manual Website www baudcom com cn Tel 86 21 37709251 Email info baudcom com cn 18 Then turn on the power you will see the page as follows Enter the password to enter the configuration interface...

Страница 20: ...ing as follows help This command shows current application program version program name and the internal commands list of the system as follows You can also use the help command to show help informati...

Страница 21: ...s community This command configures the read only group name and read write group name Group name is the concept of SNMP agreement like the password Use the command community ro to configure the read...

Страница 22: ...upgrades Management Information Base MIB is the organized hierarchical information set Use SNMP to visit these MIB They are composed of manageable information and identified by the object identifier S...

Страница 23: ...ace Click Set Paraments to enter Set Paraments interface as follows The Item and Items columns list the parameters that can be changed the Current column lists the present parameter values the New col...

Страница 24: ...formance and in some cases distortion performance We recommend that you clean all mating fiber connectors before connecting them to an optical transmitter In addition if you suspect that the optical c...

Страница 25: ...sted in Table 6 1 Table 6 1 Troubleshooting Solutions Indicator status Alarm menu content Fault phenomenon Solution Power indicator is yellow Power Invalid LEFT RIGHT The left right power is break dow...

Страница 26: ...Customer Service None None The optical output power is lower than the nominal value Check the fiber connector Follow the connector cleaning procedure see Section 6 1 If that does not correct the prob...