Andromeda MAX VAP mod.2009 v1.1
pag. 10
gennaio 2009
17.
INTERVENTIONS AND SMALL REPAIRS
The following procedures may be carried out by an Authorized Service Centre or by
the customer (boiler MUST be cold and plug MUST be disconnected from the mains):
1.
replacement of the cover every 700 hrs. (the respective icon will appear on the
display).
N.B.:
the cover can be washed;
2.
replacement of the iron
(fig. 1)
;
3.
replacement of the coil of the solenoid valve
(fig. 1 solenoid-valve)
;
4.
replacement of the steam hose
(fig. 4)
;
5.
cleaning of the water inlet filter (the respective icon will appear on the display).
See “cleaning of water filter”;
6.
cleaning of the boiler probe;
7.
cleaning of motor (do as follows):
-
switch the current off;
-
open the rear panel;
-
clean the inside with compressed air;
8.
the ANDROMEDA MAX VAP was designed to work maximum 8 hrs. per day, 5 days
a week. In these conditions the machine is expected to function for 7 years.
18.
CLEANING OF WATER FILTER
The cleaning of the filter is to be done whenever the warning is displayed. If the water is full
of impurities, cleaning should be done more often.
To clean the water filter:
1.
turn off the main water supply tap;
2.
unscrew the filter plug by using a wrench as
shown on the left;
3.
take out the filter;
4.
by using running water, clean the filter in order to
eliminate all impurities;
5.
re-assemble the filter, fix with the wrench and turn
on the main water supply tap, checking at the
same time that there are no leakages.
19.
CLEANING OF THE BOILER PROBE
To clean the probe of the boiler, do as follows:
1.
open the rear panel of the machine;
2.
find the boiler and the probe;
3.
unscrew the probe by using a wrench and take it out;
4.
clean the probe with fine grain scrubbing paper in order
to eliminate all encrustation;
5.
re-assemble the probe and check that there are no
leakages when the boiler is under pressure.
PROBE