background image

Rev. A-061015 

  Page 4 

P/N VDC1215C-MNL

BatteryMINDer

® 

  

 

Model 1215C

6.  Do not operate charger with damaged cord or plug – replace the 

cord or plug immediately.  

7.  Do not operate charger if it has received a sharp blow, been dropped, 

or otherwise damaged in any way; call 

VDC Electronics Tech 

Support Dept. 800.379.5579 x6 (ET)

 for advice.  

8.  Do not disassemble charger; call 

VDC Electronics Tech Support 

Dept. 800.379.5579 x6 (ET)

 for advice when service or repair is 

required.  Incorrect reassembly may result in a risk of electric shock 
or fire.  

9.  To reduce risk of electric shock, unplug charger from outlet before 

attempting any maintenance or cleaning.  

10. WARNING – RISK OF EXPLOSIVE GASES

11.  WORKING IN VICINITY OF A LEAD-ACID BATTERY IS 

DANGEROUS.  BATTERIES GENERATE EXPLOSIVE GASES 
DURING NORMAL BATTERY OPERATION.  FOR THIS REASON, 
IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE 
INSTRUCTIONS EACH TIME YOU USE THE CHARGER.  

12. To reduce risk of battery explosion, follow these instructions and 

those published by manufacturer of any equipment you intend to use 
in vicinity of battery.  Review cautionary marking on these products 
and on engine.  

13. PERSONAL PRECAUTIONS

14. Consider having someone close enough by to come to your aid when 

you work near a lead-acid battery.  

15. Have plenty of fresh water and soap nearby in case battery acid 

contacts skin, clothing, or eyes.  

16. Wear complete eye protection and clothing protection.  Avoid 

touching eyes while working near battery.  

17.  If battery acid contacts skin or clothing, wash immediately with soap 

and water.  If acid enters eye, immediately flood eye with running cold 
water for at least 10 minutes and get medical attention immediately.  

18. NEVER smoke or allow a spark or flame in vicinity of battery or 

engine.  

Содержание 1215C

Страница 1: ...43 www BatteryMINDers com techsupport vdcelectronics com Tech Support 800 379 5579 x6 ET M F Rev A 061015 P N VDC1215C MNL BatteryMINDer 1215C 12 Volt 1500 mA Convertible Charger Maintainer Desulfator...

Страница 2: ...UP OPERATING INSTRUCTIONS 10 CHARGING STAGES 10 ADDITIONAL FEATURES 10 ATTACHING BATTERYMINDER 1215C 11 TROUBLESHOOTING 12 MAINTAINING MULTIPLE BATTERIES 12 VOLTAGE TABLE 12 CHARGING CURVE 13 SAFETY...

Страница 3: ...ry Use of improper extension cord could result in a risk of fire and electric shock If an extension cord must be used make sure a That pins on plug of extension cord are the same number size and shape...

Страница 4: ...RING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER 12 To reduce risk of battery explosion follow these instructions...

Страница 5: ...re above 123 F 23 PREPARING TO CHARGE 24 If necessary to remove battery from vehicle to charge always remove grounded terminal from battery first Make sure all accessories in the vehicle are off so as...

Страница 6: ...o reduce risk of damage by hood door or moving engine part 42 Stay clear of fan blades belts pulleys and other parts that can cause injury to persons 43 Check polarity of battery posts POSITIVE POS P...

Страница 7: ...RY 51 Check polarity of battery posts POSITIVE POS P battery post usually has a larger diameter than NEGATIVE NEG N post 52 Attach at least a 24 inch long 18 gauge AWG insulated battery cable to NEGAT...

Страница 8: ...nt Temperature Sensor 4 Temperature Sensor input connector 5 Output cord with quick connect plug tethered cap not shown 6 Fully Insulated Battery Clip cord set Aircraft Grade with 15A replaceable fuse...

Страница 9: ...ndition detected for 3 sec initial battery 10 5V OFF OFF ON 5 AC Power connected soft start charging bulk charging and absorption charging FLASH FLASH ON 6 Sulfation check mode FLASH OFF ON 7 Maintena...

Страница 10: ...or both SAFETY as well as performance reasons Constant Current This stage recharges battery to 85 of its present capacity before automatically switching to Absorption stage Absorption completes the fu...

Страница 11: ...ance stage M Voltage during the Maintenance stage Model Battery Types MV CV M 1215C 12V Lead Acid 3 0V 14 4V 13 4V All readings must be taken at 77 F 25 C Attaching BatteryMINDer 1215C NOTE When not c...

Страница 12: ...ery possibly causing catastrophic failure Once the batteries are charged use 18 gauge or greater wire to connect the batteries or for greatest safety protection and ease of use consider investing in t...

Страница 13: ...arging 0 35A 13 4V 25 18 hours timer 10 minutes Charging current 0 Time 100 hours timer limited 5 hours timer limited g n i g r a h C n o i t p r o s b A g n i g r a h C k l u B 1 5A 14 4V 25 Full tim...

Страница 14: ...Electrical Cable Physical Parameters BatteryMINDer 1215C 12VDC 1 5A Input 100 240 VAC 50 60 Hz 0 4A Input Cord SJTW 18AWG X2 105 C 12 5 with UL 2pin plug Output Cord 6 SPT 2 18AWG X2 105 C with quick...

Страница 15: ...nics In the event that you believe your product may be defective you MUST speak to a VDC Electronics technician at 1 800 379 5579 x6 ET before proceeding further NOTES MODEL BatteryMINDer 1215C SERIAL...

Страница 16: ...ir or Replacement section of this manual for additional information BatteryMINDer One Year 100 Unconditional Money Back GUARANTEE This BatteryMINDer product is guaranteed to perform as claimed or WE w...

Отзывы: