background image

Part Number: DBDC10 / DBDC20

DC to DC 

Dual Battery Charger 

Manual

 

For your personal safety read, understand and follow  

the information provided in this instruction manual.

Содержание DBDC10

Страница 1: ...Part Number DBDC10 DBDC20 DC to DC Dual Battery Charger Manual For your personal safety read understand and follow the information provided in this instruction manual...

Страница 2: ...a Inadequate ventilation may over heat the charger and cause in efficient operation This battery charger is not intended for outdoor operation Do not expose it to moisture or extreme weather condition...

Страница 3: ...control Fully automatic hi frequency multi stage charging Pulse mode technology that reduces oxidation evens electrolyte consistency and minimizes temperature equating to longer battery life Easy push...

Страница 4: ...minimum specifications Locate where you are going to install the DC DC charger Ensure the charger is located in a suitable non wet area in the vehicle or caravan Ensure the charger is securely mounte...

Страница 5: ...ther end of the twin core cables Connect the auxiliary battery to shared negative and charger output using twin core wiring as per recommended cable size Using the twin core wiring laid between the ma...

Страница 6: ...ltage reaches 13 4 volts the charger will begin to charge the auxiliary battery The initial default setting is for lead acid batteries If you are charging a battery with a different chemistry simply c...

Страница 7: ...output or vehicle battery below 12 5V Output Current DBDC10 DBDC20 10A 20A Minimum StartVoltage 1 5Volts for battery being charged Charge Control Soft Start Yes Bulk Charge 14 3V Gel 14 7V SLA 15 6V...

Страница 8: ...Charging voltages GEL LEAD ACID CALCIUM Charging 14 8V 15 2V 16 2V Boost 14 3V 14 8V 15 6V Float 13 3V 13 7V 13 7V Charging algorithm will change according to battery type...

Страница 9: ...ore if the 100AH battery is operating only the fridge and receives no additional charge it ideally will require recharging after 48 hours To replenish these 48 amp hours using a 10 amp DC DC charger w...

Страница 10: ...age Example headlights left on for several hours then vehicle required jump starting 3 Has not been recharged or used in past 3 months 4 Has been stored in a discharged state 5 Has any evidence of dam...

Страница 11: ...ck condition of batteries Check performance of alternator Batteries that are over 3 years old severely discharged or previously been severely discharged not regularly recharged over heated low in elec...

Страница 12: ...ok place Haigh Australia Pty Ltd bears reasonable expenses for claiming under the warranty You must submit details and proof to Haigh Australia Pty Ltd for consideration This warranty is provided in a...