Battery Fighter BCA1102S6WR Скачать руководство пользователя страница 3

BCA1382S6WR - 140728 

c. 

Connect the positive (red) clip from the battery charger to the positive (pos, +) post of battery. 

d. 

Position yourself and the free end of cable as far away from battery as possible, then connect negative (black) 
clip from the battery charger to free end of cable. 

e. 

Do not face battery when making final connection. 

f. 

Connect charger AC supply cord to an electric outlet. 

g. 

When  disconnecting  the  charger,  always  do  so  in  reverse  sequence  of  connecting  procedure  and  break  first 
connection while standing as far away from battery as practical. 

h. 

A  marine  (boat)  battery  must  be  removed  and  charged  on  shore.  To  charge  it  on  boat  requires  equipment 
specially designed for marine use. 

 

OPERATING INSTRUCTIONS: 

 
AUTOMATIC MONITORING 

– Your new battery charger is completely automatic and can be left on whenever input power is 

made available to the charger. The charger output depends on the condition of the battery it is charging. When the battery is 
fully  charged,  the  indicating  light  will  turn  green  and  the  charger  will  switch  itself  to  a  storage  charge  mode  and  will 
automatically monitor and maintain the battery at full charge. 
 
CABLE  CONNECTIONS 

 

Your  new  battery  charger  is  equipped  with  two  output  leads,  a  red  positive  lead,  and  a  black 

negative clip lead and an OBD II cable for data backup during battery replacement. Always connect or disconnect the output 
leads before plugging into AC power. 
 
For all battery types: Connect the red positive (+) lead to the positive terminal of the battery. Connect the black negative (-) 
lead to the negative terminal of the battery. 

 

NOTE: 

If  the  charger  is  left  connected  to  a  lead  acid  battery  for  long  periods  of  time,  check  water  levels  periodically  as 

directed by the battery manufacturer to ensure electrolyte is maintained at proper level.

 

 
ATTENTION:  THE  BATTERY  CHARGER HAS  A  SPARK  FREE, WRONG POLARITY  & SHORT  CIRCUIT  PROTECTION 
CIRCUITRY BUILT IN - BUT AS A GOOD PRACTICE, NEVER ALLOW THE TWO CLIPS TOUCH EACH OTHER. 
 
The Battery Charger will not produce voltage (turn on) until it recognizes at least three volts from the battery. The battery 
charger clips 

must

 be clipped to a battery in the correct polarity to initiate output voltage and begin charging when in 

Lead Acid (Pb) charge mode. 

 

When in Lead Acid (Pb) charge mode if the charger is hooked up in reverse polarity, the 

“Reverse Polarity” light will flash 

indicating that the connection has been made in reverse of the polarity of the battery and  a charge has not been initiated. 
The clips must be re-connected in the proper polarity to start the charger, Red to Positive (+ to +) and Black to Negative (- to 
-). 

 
NOTE: DO NOT TURN YOUR BATTERY CHARGER ON AND OFF REPEATEDLY (Plug and Unplug) WITHIN A SHORT 
PERIOD. IF THIS HAPPENS, UNPLUG BATTERY CHARGER FROM AC POWER, WAIT FOR ONE MINUTE AND THEN 
CONNECT THE CHARGER AGAIN TO RESTART CHARGING CYCLE. 

 

FULLY DISCHARGED BATTERIES - Lead Acid (Pb) Charge Mode:   

If your battery is totally discharged (below 3 volts), the BATTERY CHARGER circuitry will not start due to its internal safety 
circuit.  The  internal safety circuit of  the  battery  charger must sense more than  3  volts  in  the  battery before  it  will  allow  the 
charging circuit to turn on. Otherwise, the charger is inoperable. In this case (battery voltage between 0.5V ~ 3.0V), the Bad 
Battery  Indicator  Light  will  flash,  which  means  charging  has  not  been  initiated.  If  the  battery  voltage  is  less  than  0.5V,  the 
charger will be returning to STANDBY mode. 

Note:

 Unless the battery was rapidly discharged (lights left on overnight) most 12 volt lead acid batteries that are at a state of 

charge that is less than 9 volts are likely to be worn out or defective. 

 
72-HOUR SAFETY FEATURE: 

A 72 hour Safety Timer will commence anytime the charger is on. This feature is designed to protect marginal batteries from 
over  charging.  If  the  battery  voltage  reaches  the  proper  level  within  72  hours,  the  charger  will  automatically  switch  to 
maintenance mode. If your battery is marginal or defective, the Battery Charger will stop all the charging processes in order 
to protect the marginal battery from over charging. Please check battery condition as it could also indicate that a very large 
(high capacity) but good battery is simply not yet fully charged. When this happens, the bad battery indicator will be flashing. 
If this is the case, please contact your local dealer and have the battery tested. 

 

 

 

 

 

Содержание BCA1102S6WR

Страница 1: ...fic precautions such as removing or not removing cell caps while charging and recommended rates of charge 10 Do not use the battery charger unless the battery voltage matches the output voltage rating...

Страница 2: ...area or restrict ventilation in any way e Do not set a battery on top of charger CONNECTION PRECAUTIONS Connect and disconnect DC output clips only after setting the charger switches to off position a...

Страница 3: ...battery charger clips must be clipped to a battery in the correct polarity to initiate output voltage and begin charging when in Lead Acid Pb charge mode When in Lead Acid Pb charge mode if the charge...

Страница 4: ...ery is connected in reverse polarity please check the battery connection s and correct reverse polarity condition Make sure Red to and Black to RECOVERY Battery Recovery processes will commence if the...

Страница 5: ...e is in process B The battery is being recovered wait until the Recovery Light turns off then normal charging processes will begin Bad Battery Light On The battery is worn out or is possibly defective...

Страница 6: ...continue to accept charge as it enters the Reconditioning phase To maintain the battery at a full state of charge 5 Recondition Phase The Recondition phase follows when the Pulse Mode is completed ch...

Страница 7: ...tially ensures the battery is in good condition prior to launch of normal charge processes as a safety measure charge processes will not begin if battery is below 3 volts 2 Bulk Charge Phase Bulk Char...

Страница 8: ...nce capacity ranges are suggested only as a guide for battery charger selection and application based on varied customer charging and maintenance requirements Please be sure to follow safety and use i...