Dimensions
The PreciseTemp 320 Digital Steam/Sauna Room Thermometer is designed to simplify steam and sauna room
operation and provide bathers with the information they need to make informed decisions regarding the
environment they are electing to bathe in. Mounted near the environment entry, the PreciseTemp 320 will
provide precise and reliable temperature readings to reduce operating complaints and facilitate steam and
sauna room/equipment troubleshooting.
Specifications
3.5” outside
diameter
3.16” diameter bolt
circle
0.26” diameter for
sensor cable
0.0938” diameter
holes 120° apart
2.64”
1.06”
3.5”
Figure 1
Figure 2
Material: Stainless steel body with clear plastic face
Depth: 1"
Diameter: 3-1/2"
Battery: G-13A, 1.5V, Button Cell
Sensor Cable: 8’ or 20’ Tethered (non-spliceable)
Sensor Guard: 5-1/8”W x 1-1/4”D x 2-3/8”L
Front
Side
Profile
Rear Flange
Package Includes
Thermometer Installation
Select a thermometer mounting location, outside
the bathing environment, adjacent to the entry
and at a height for comfortable bather view.
Drill a 3/8” diameter hole for sensor run.
Select a thermometer sensor mounting location
inside the bathing environment 4” down from
finished ceiling. Drill a 3/8“ diamter hole for sensor.
Route sensor into bathing environment location
and mount thermometer with provided anchors
and hardware (flangeless). Use a 3/16” drill bit
should the anchors be utilized.
1.
2.
3.
Sensor and Sensor Guard Installation
Read instructions in their entirety before starting
installation.
Once the finished wall materials are installed,
place supplied template (page 4) in location of
mounting. Center of template should be orient-
ed 1-1/2” to the right of sensor wire exit.
Level template against level line.
Affix template to wall with tape.
Recheck for level and drill (3/16” drill bit) at
designated “+” locations on template.
Apply silicon dab over corner and center sensor
mount anchor holes.
Tap wall anchors (flange) into holes with
hammer.
1.
2.
3.
4.
5.
6.
- Drill
- 3/16” drill bit
- 3/8” drill bit
- Hammer
- 7/64 Hex drive wrench
- Safety goggles
- Level
- Tape
Tools Required:
For safety purposes, use safety goggles
at all times.
Check for piping/electrical before
drilling.
2
- (1) Digital Thermometer with tethered sensor
- (1) Sensor guard, stainless steel
- (3) Wall anchors, flangeless (Digital thermometer)
- (3) 3/4” Flangeless screws (Digital thermometer)
- (3) Wall anchors, flange ((1) Sensor mount, (2) Sensor guard)
- (3) 1” Flange screws ((1) Sensor mount, (2) Sensor guard)
- (1) Sensor screw mount
- (1) Sensor tie
- (1) RTV silicon sealant, 1 oz tube
- (1) Mounting template