background image

13

7

9

8

12

6

14

4.

Test the  lift on  dry  ground using the  Up/Down Switch

   (  # 9)  and  the  Key  Fob Transmitters.  Inspect the

       system for leaks.

1.

The Hydraulic Pump will arrive fully assembled.  Make

   s  u re all the connections are snug to prevent leaks or

      loss of power to the unit.

2.

Install two Group 31 Marine Grade Batteries as shown

   a  b ove. 

Confirm that the POWER switch on the Control

      Panel (#8) is OFF.

 Connect the two solar panels to the

      batteries as shown - each panel connects to one battery.

      Connect the short Link Cable (#19) between the positive
      terminal of one battery and the negative terminal of the
      other. Connect the Red Battery Cable (#12) to the
      positive terminal of the right battery and the Black Battery
      Cable  (#13) to the negative terminal of the left battery. 

NOTE:  

       Ensure  battery  cables  are  correctly  connected
  and  their  terminals  are  tight  (use  pliers).

3.

Slide the Hydraulic Cylinder Hoses (#14) through the

   a

  c cess holes in  the side of  the White Fiberglass Box

       (#10) and attach them to  their corresponding
       Quick Couplers (#4, #5).

 

Ensure  each  Quick  Coupler  is

completely  seated  and 

tight

  with

no  gap  at  the  connection  joint.

Connection must be 

tight

 to open internal

check valve and allow fluid to flow. USE PLIERS

one

inch

hydraulic fluid level with

lift in DOWN position

only add fluid with lift

in DOWN position

H

y

d

ra

u

li

P

o

w

e

U

n

it

13

page 14

step

OIL  INJECTED  INTO  THE  SKIN  FROM  HIGH  PRESSURE
LEAKS  IN  HYDRAULIC  SYSTEMS  CAN  CAUSE  SEVERE
INJURY.  MOST  DAMAGE  OCCURS  DURING  THE  FIRST
FEW HOURS. SEEK MEDICAL ATTENTION IMMEDIATELY.
SURGICAL  REMOVAL  OF  OIL  MAY  BE  NECESSARY.

Keep inside dry

2

NO GAP!

4

5

Tighten wingnuts on 

batteries very tight.

Otherwise, cables 

may overheat 

during lift 

operation. 

NOTICE

19

+

+

From

Solar Panels

From

Solar Panels

Battery

Group 31

marine

deep cycle

Battery

Group 31

marine

deep cycle

From

Solar Panels

Isolation Diode

Isolation Diode

To Pump

To UP-DN Switch

Содержание Over-Center 18k59

Страница 1: ...y or operation tm Over Center Hydraulic Steel Lift 18 000 lbs Capacity Models 18k59 18k71 ASSEMBLY INSTALLATION REPLACEMENT PARTS 18k59 71 11 21 L392 0067 REV D Copyright 2015 Basta Marine 866 GO BAST...

Страница 2: ...rvice your lift regularly Do not service the unit with the boat on the lift Use a mooring line for additional security Only use Basta Marine approved oil in lift Special biodegradable non toxic hydrau...

Страница 3: ...SURE LEAKS IN HYDRAULIC SYSTEMS CAN CAUSE SEVERE INJURY MOST DAMAGE OCCURS DURING THE FIRST FEW HOURS SEEK MEDICAL ATTENTION IMMEDIATELY SURGICAL REMOVAL OF OIL MAY BE NECESSARY USE ONLY BASTA APPROVE...

Страница 4: ...he following pages various symbols are used indicates an illustration for a procedure indicates a major part shown and described above indicates a hardware item shown and described on page 5 12 1 C3 8...

Страница 5: ...SS 3 8 flat washer SS 3 8 flat washer SS 3 8 flat washer galvanized 3 8 nylon insert lock nut SS 3 8 nylon insert lock nut SS 3 8 lock washer galvanized 3 8 hex nut galvanized 3 8 x 3 hex head cap scr...

Страница 6: ...ad set screws 5 8 x 1 1 2 REF A1 apply a small amount of grease to bolt threads HARDWARE 1 1 2 2 tighten leg set screws alternately to push the leg securely into the corner of the leg socket A1 A1 A1...

Страница 7: ...s apply a small amount of grease to bolt threads apply a small amount of grease to bolt threads HARDWARE HARDWARE do not tighten these bolts completely until the H frames and bunks have been installed...

Страница 8: ...ts 1 x 9 REF C1 2 2 flat washers lock nuts 1 1 C2 C3 4 apply a small amount of grease to bolt threads HARDWARE 4 5 6 remove the plastic ties that secure the bushings before installing the H frame C1 C...

Страница 9: ...hreads apply a small amount of grease to bolt threads HARDWARE HARDWARE C2 C3 C1 2 2 bolts bolts 1 x 9 1 x 9 C1 C1 2 2 2 2 flat washers flat washers lock nuts lock nuts 1 1 1 1 C2 C2 C3 C3 remove the...

Страница 10: ...F D1 6 6 flat washers lock nuts 3 4 3 4 D2 D3 7 apply a small amount of grease to bolt threads HARDWARE tighten these nuts only finger tight until the cylinders are installed 7 7 7 7 7 8 8 9 9 7 D3 D1...

Страница 11: ...3 32 x 2 3 32 x 2 3 4 X 5 3 4 X 5 REF REF E2 E2 E1 E1 8 9 HARDWARE HARDWARE E1 E2 E2 E1 install the clevis pins E2 with their heads toward the inside of the lift page 11 step step INSIDE INSIDE NOTIC...

Страница 12: ...lock nuts 1 2 1 2 F2 F3 10 apply a small amount of grease to bolt threads HARDWARE leave bolts loose until bunk boards are installed 10 F3 F2 F1 page 12 step 10 10 10 12 11 at each bunk board 50 92 92...

Страница 13: ...REF J1 J2 J3 G2 H2 G3 H3 H1 G1 12 11 apply a small amount of grease to bolt threads apply a small amount of grease to bolt threads HARDWARE HARDWARE the bunks may have to be adjusted several times for...

Страница 14: ...use pliers 3 Slide the Hydraulic Cylinder Hoses 14 through the access holes in the side of the White Fiberglass Box 10 and attach them to their corresponding Quick Couplers 4 5 Ensure each Quick Coup...

Страница 15: ...L ASSEMBLY R815 0002 14 H123 0019 hydraulic hose assembly 15 H412 5302 hydraulic cylinder 16 H791 0005 hydraulic fitting kit 20 H111 0002 hydraulic hose ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER D...

Страница 16: ...14 apply a small amount of grease to bolt threads HARDWARE up to four centering devices per side can be installed 14 step 14 14 16 15 14 position as desired position as desired position as desired po...

Страница 17: ...EF M1 M2 M3 L1 16 15 apply a small amount of grease to bolt threads apply a small amount of grease to bolt threads HARDWARE HARDWARE remember to tighten all the bolts installed in Step 10 note how bun...

Страница 18: ...oatlift can be raised into the full Over Center position without settling tm 3 Remove the boat Verify that the lift frame is level Re level the framework if necessary NOTE If you purchase a new boat b...

Страница 19: ...inch hydraulic fluid level with lift in UP position NOTICE USE ONLY BASTA APPROVED BIODEGRADABLE HYDRAULIC FLUID We recommend Chevron Clarity AW ISO 32 or CITGO Aquamarine 46 hydraulic oils DO NOT ad...

Страница 20: ...t c h p o w e r o f f w h e n n o t i n u s e O f f M a i d i n t h e U S A M a n u f a c t u r e d u n d e r o n e o r m o r e o f t h e f o l l o w i n g p a t e n t s 6 3 1 8 9 2 9 6 8 3 7 6 5 1 4...

Страница 21: ...re not screwed together tight enough built in check valves will not allow fluid to flow See Page 14 A Check the fluid level See Page 19 FOR ASSISTANCE OR SERVICE Contact your local dealer or call 1 86...

Страница 22: ...eft unattended on the lift make sure it is raised into the over center position Otherwise unintended motion may occur 9 Be sure the lift frame remains level If the lift has settled unevenly it may be...

Страница 23: ...include that the Product or part be Returned to Company for inspection at the Purchaser s initial expense Replacement parts for Products outside the United States will be shipped in the next authoriz...

Страница 24: ...t lift or canopy legs Load Guides Designed to make loading your boat straight and true amazingly easy even in cross winds and active water Light kit Install these lights above or below the water They...

Отзывы: