Installation Guide
24
Basler IP Fixed Box Cameras
Gnd
Alt. Camera
Power
RS-485 B-
RS-485 A+
DC Out
5
2
3
8
1
6
+12 to +24
VDC
+24
VDC
Max
Switch
Device
RS-485 Gnd
RS-485 A+
RS-485 B-
Camera
+5
VDC
+5
VDC
1 k
Ω
+5
VDC
1 k
Ω
I/O-2
(Set as an output)
(Set as an output)
I/O-1
4
I/O-0
+5
VDC
1 k
Ω
(Set as an input)
7