Physical Interface
Basler ace USB 3.0
79
5.13 Checking the Status of the I/O Lines
5.13.1 Checking the Status of an I/O Line
You can determine the current status of any I/O line that depends on whether an electrical signal is
applied to the line and whether the line inverter is disabled or enabled. In addition, factory settings
determine fundamentally whether a given electrical signal level will be considered to correspond to
a "high" or "low" line status.
For example, consider output line Line 2:
When no electrical signal (output signal) is applied and when the line inverter is disabled, the
signal level will be "high" according to factory settings and the LineStatus parameter value will
be "true" (see
Table 16
).
When an electrical signal is applied and when the line inverter is disabled, the signal level will
be "low" and the LineStatus parameter value will be "false".
When no electrical signal is applied and when the line inverter is enabled, the signal level will
be "low" and the LineStatus parameter value will be "false" (see
Table 17
)
When an electrical signal is applied and when the line inverter is enabled, the signal level will
be "high" and the LineStatus parameter value will be "true"
The signal levels and corresponding LineStatus parameter values for all I/O lines are listed below,
depending on whether an electrical signal is applied (as indicated by electrical signal level) and
whether line inverters are enabled
(Table 16
through
Table 19).
Note that certain combinations of
electrical signal levels and line inverter settings result in identical line status (compare
Table 16
and
Table 19
on one hand and
Table 17
and
Table 18
on the other).
No electrical signal applied and line inverters disabled:
The line status of a GPIO line (Line3, Line 4) does not depend on the configuration
of the GPIO line for input or output.
I/O Line
Electrical Signal /
Electrical Signal
Level
Logical LineStatus
Parameter Value
Binary Expression
of the Line Status
Parameter Value
Line 1 (input)
Off/Low
False
0
Line 2 (output)
Off/Low
True
1
Line 3 (input/output)
Off/Low
True
1
Line 4 (input/output)
Off/Low
True
1
Table 16: I/O Lines and Line Status With no Electrical Signals Applied and All Line Inverters Disabled
Содержание acA2000-165
Страница 4: ......
Страница 10: ...Table of Contents AW00123402000 vi Basler ace USB 3 0...
Страница 44: ...Specifications Requirements and Precautions AW00123402000 34 Basler ace USB 3 0...
Страница 46: ...Installation AW00123402000 36 Basler ace USB 3 0...
Страница 50: ...Camera Drivers and Tools for Changing Camera Parameters AW00123402000 40 Basler ace USB 3 0...
Страница 94: ...Physical Interface AW00123402000 84 Basler ace USB 3 0...
Страница 262: ...Features AW00123402000 252 Basler ace USB 3 0...
Страница 268: ...Revision History AW00123402000 258 Basler ace USB 3 0...