Basic Operation & Standard Features
BASLER A640
f
3-17
DRAFT
Figure 3-9: Exposure Start Controlled with an ExTrig Signal
You can calculate the frame readout time with this formula:
Frame Readout Time = ( AOI Height x 52.55 µs ) + C
Where: C = 6557.8 µs for monochrome cameras
C = 6610.35 µs for color cameras
You can calculate the frame transmission time with this formula:
Frame Transmission Time = Packets/frame x 125 µs
To calculate the transmission start delay, use the following information:
If the frame transmission time is greater than the frame readout time:
Start Delay = 125 µs.
If the frame transmission time is less than the frame readout time:
Start Delay = (Readout Time - Transmission Time) + 125 µs