Security ON/OFF

IP camera settings

There is from 1 to 8 IP cameras available
for display.

 

Select a camera in the list
by

 

scrolling through

 

the list and clicking

on the camera name.

Stop button

Play button

Zone settings

 

№: 

Number of the sensor.

 

Type: 

Type o the sensor.

Normal mode

 - the sensor is activated only when the system

is armed and if this sensor is selected in the paragraph above.
Usually this type is used for door and window sensors.

Emergency and 24 hours

 - is active constantly.

These types can be selected when flood sensors, gas, volume,
smoke and heating are connected to the loops.

 

Mode: 

Mode of the sensor.

It depends on the sensor used.

 

3C 

- activation is performed when switching position

 

NO

 - normally open sensor, activation is performed when

the contacts are closed

 

NC 

- normally closed sensor, activation is performed when

the contacts open

 

Bell 

- doorbell connection mode. When the contacts are

closed, the monitor will start playing the incoming call melody.

 

Delay: 

Delay before activating a specific sensor.

 

Sensor:

 Selects the display type of the sensor

for additional informativity when triggered.

Display during an alarm

By setting the required value for the
connected sensor, the sensor number
and its name will be displayed on the
monitor when the alarm is triggered.

Display 

with zone settings

Main security display

To disable alarm you need to enter password.

By default, password is 

1234

.

Содержание AU-04LA

Страница 1: ...ssible with the help of mechanical keys and a touch screen Classic black and white body color suitable for any style One of the interesting features of the AU 04LA is the ability to connect an additio...

Страница 2: ...us Security menu SIP status Missed calls Weather Security menu Home automation menu Intercom menu Service menu Settings menu News line Main screen Security menu In this menu you can turn on o the alar...

Страница 3: ...of the sensor It depends on the sensor used 3C activation is performed when switching position NO normally open sensor activation is performed when the contacts are closed NC normally closed sensor a...

Страница 4: ...he house Home and Sleep Depending on each scenario you can customize the logic of the triggering of various loops Activation time The time after which a particular scenario is activated Settings Old p...

Страница 5: ...s of lights to be controlled in separate rooms using module SH 62 Air conditioning This menu allows controlling air conditioners in separate rooms Curtains This menu allows controlling curtains in sep...

Страница 6: ...ton then enter from 1 to 4 digits of the apartment number and press the button call To delete an incorrectly entered digit use the Delete button Calls between additional monitors To call additional in...

Страница 7: ...Right arrow buttons In this mode communication will take place in one way mode i e You will hear what is happening at the panel but you will not be heard Records Incoming calls Outgoing calls Missed...

Страница 8: ...necessary to set 0 in this line If there are several monitors then the numbering should begin with 0 and end with 8 Sync code Synchronization code between monitors and panels for intercom settings Co...

Отзывы: