BASEWEST TS-420 Скачать руководство пользователя страница 7

BASEWEST

 

Operating & Maintenance Manual 

 

Model TS-420 Test Set 

Page 7 of 10

 

25-60-41 

24 Jan 2002 

 

 

 
 

Figure 4.  Internal Battery Charging Arrangement 

 
 
c)  The  battery  should  be  left  on  charge  for  approximately  eight  (8)  hours,  or  overnight.  

After  charging,  disconnect  the  charger  and  place  the  Mode  Selector  switch  into  the 
AMMETER position and Press-To-Test.  If the Self-Test indicator illuminates GREEN, 
and  the  Battery  Status  indicator  is  OFF,  the  unit  is  sufficiently  charged  to  return  to 
service. 

 
 

NOTE

:  If the unit must be used before full charge is reached, the unit may be returned 

to  service  temporarily  if  the  Self-test  indicator  and  the  Battery  Status  indicators  are 
both  on  (GREEN  and  AMBER,  respectively).    The  unit  MAY  NOT  be  returned  to 
service if the Self-Test indicator is RED. 

 
d)  If the Self-Test indicator comes on RED after a full charge cycle, the test set should be 

returned to BaseWest for service. 

 

 
5.3  Battery Replacement 

 
The internal rechargeable Ni-Cad battery should provide several years of service.  Use the 
following procedure to replace the battery when necessary. 
 
a)  Turn the test set face down on a stable surface.  Remove four (4) screws on bottom of 

instrument case. 

Charger Receptacle 

AC Charger 
P/N 36-1002 

Содержание TS-420

Страница 1: ...Operating Maintenance Manual Model TS 420 Test Set Revision A 22 June 2010 BaseWest Inc 4240 116 th Ave N Clearwater FL 33762 Tel 727 573 2700 Fax 727 573 4307 E mail info basewest com www basewest com 25 60 41 ...

Страница 2: ...allows the selection of closed circuit test under selectable resistive loads as well as an open circuit no load test Ammeter with integral power supply This mode is used to verify the current draw of the slide light harness through an internal regulated 5VDC power supply Current readings can be used to verify proper function of the light harness and in some cases can be used as an indicator of a l...

Страница 3: ... under test is subjected to the resistive load selected by the panel mounted rotary switch Positions A through F are resistive loads exactly matching those of test equipment described in slide manufacturer manuals a NO LOAD position is offered to allow open circuit voltage testing of the battery The Battery Status indicator is not active in this mode 2 3 Ammeter Mode This mode is used to measure t...

Страница 4: ...t test load setting The NO LOAD position provides an open circuit test of the battery pack 3 4 Press To Test record voltage of the battery pack under the selected condition The Self Test indicator must illuminate GREEN at this point If not see Section 6 0 3 5 Release the Press To Test switch when the voltage is recorded The test set will return to the OFF condition NOTE This test can also be accom...

Страница 5: ...ght harness to be tested to the connector block at the head of the instrument See Figure 3 according to the following configuration options a Installed slide light systems with battery packs Connect the battery pack s 4 contact test lead plug to the 4 pin receptacle on the instrument s connector block Ammeter Power Supply connection for Light Harness Test System Test connection for Battery Light H...

Страница 6: ...5 0 NOTE If the Self Test indicator is on GREEN and the Battery Status indicator is on AMBER the test set is OK for test but should be recharged at the next opportunity 4 4 Read current milliamperes on the digital meter Confirm that the current reading is within OEM specified tolerances 5 0 Internal Battery Recharging and Replacement 5 1 General The TS 420 is provided with a rechargeable Ni Cad pa...

Страница 7: ...st be used before full charge is reached the unit may be returned to service temporarily if the Self test indicator and the Battery Status indicators are both on GREEN and AMBER respectively The unit MAY NOT be returned to service if the Self Test indicator is RED d If the Self Test indicator comes on RED after a full charge cycle the test set should be returned to BaseWest for service 5 3 Battery...

Страница 8: ...llow it to the connector on the PC board While securing the instrument with one hand carefully disconnect the battery connector from the PC board and remove the battery NOTE The battery is secured by mating patches of Velcro Use care in removing the battery pack do not use excessive force Figure 6 Battery Removed Battery Pack Battery Connector Velcro Patch Hook Attached to Test Set Velcro Patch Pi...

Страница 9: ...or repair 6 2 Ammeter Mode The following Indications apply with the instrument switched to the AMMETER mode and the Press To Test button is pushed a Self Test indicator is GREEN Battery Status indicator is OFF Test set is operational and OK for test battery charge level is medium to high b Self Test indicator is GREEN Battery Status indicator is AMBER Test set is operational and OK for test but in...

Страница 10: ...ice is splash resistant but not waterproof do not allow the device to sit in standing fluids or subject to rain Excessive exposure to UV can affect the LCD meter 7 4 Surface cleaning only with a slightly damped cloth water or alcohol is recommended DO NOT use other solvents or cleaners 8 0 Calibration and Repair The TS 420 test sets should be calibrated in accordance with the user s quality assura...

Отзывы: