•  Never connect the product to the mains immediately after it has been brought 

from a cold room into a warm one (e.g. after being transported). The resulting 

condensation may destroy the product or cause an electrical shock! Let 

the  product  reach  room  temperature  first.  Wait  until  the  condensation  has 

evaporated ; this may take several hours. Only then may the product be mounted 

and connected to the mains.

d) Using the product

• 

Do not overload the product! Pay attention to the connection specifications in the 

"Technical data" section.

•  Never touch or operate the product if your hands are moist or wet. This may 

cause a fatal electrical shock!

• 

Never pour liquids over or near the product. This constitutes a serious fire hazard 

and may result in a fatal electrical shock.
If liquid does enter the interior of the power strip, immediately isolate the product 

from the mains (turn off fuse/automatic fuse/residual current circuit breaker for 

the corresponding circuit). Then disconnect any connected devices (e.g. USB 

device) from the product. Consult an technician. Do not continue to use the 

product.

•  Only use the product in temperate climates, not in tropical climates.
•  Do not use the product if it is damaged. This may cause a fatal electrical shock!

Operating elements

1 USB-A sockets
2 Power socket
3 Cover frame
4 Socket module
5 Screw holes
6 Neutral wire
7 Earth wire
8 Phase
9 Mounting plate

Operation

•  Only connect and mount the product when it is isolated from the mains voltage.
•  Isolate all poles of the mains cable from the mains supply by removing the electric circuit fuse 

or switching off the automatic fuse. Then turn off the earth leakage circuit breaker. Protect it 

against an unauthorised restart, e.g. with a danger sign.

•  Check that the mains cable is isolated from the mains, e.g. with an appropriate testing device.
•  Remove the power socket module (4) and the cover frame (3) from the mounting plate (9). 

Secure  the  mounting  plate  to  the  surface-mounted  or  flush-mounted  box  using  the  two 

screws included with the product.

•  Connect the mains cable (1.5 to 2.5 mm² cable cross section) to the terminal connections. 

The wires must be stripped to a length of approximately 10 mm.
L (8) = Phase
N (6) = Neutral wire
PE (7) = Earth wire

To remove a wire from a terminal connection, loosen the screw and pull the wire out of the 

connection.
•  Click the socket module (4) into the mounting plate.
•  Be careful not to damage the cables when inserting the socket module (4) or tightening 

screws.

•  Place the cover frame (3) on the power socket.

Operation

•  You can connect a standard electrical device to the protective contact power socket on the 

product (i.e. it functions like a normal mains socket).

•  The socket can only be unlocked by inserting the pins of a plug into both of the socket 

openings at the same time.

•  However, you should still exercise particular caution when children are present. Children are 

unaware of the hazards resulting from the incorrect handling of electrical devices. Handling 

the product incorrectly may cause a fatal electrical shock!

•  The USB charging output (USB-A socket (1)) can be used to charge a mobile device  

(e.g. smartphone or tablet). Connect the mobile device to the USB charging output using a 

suitable cable. 

•  Ensure that the USB plug is inserted into the USB socket in the correct orientation. Do not use 

any force when connecting the USB plug.

•  Observe the information about charging times in the instruction manual for the product that 

you have connected to the USB charging output.

•  The USB charging output is only designed to provide power to the connected USB device.  

It cannot be used to transfer data.

Care and cleaning

•  You do not need to carry out maintenance work on the product. Leave maintenance or repair 

work to an expert.

•  Disconnect the product from the power supply before cleaning (turn off fuse/automatic fuse/

residual current circuit breaker for the corresponding circuit).

•  Use a dry, lint-free cloth to clean the product. Dust can be easily removed using a vacuum 

cleaner.

•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could 

damage the casing or even impair the functioning of the product.

Disposal

Electronic devices are recyclable waste and must not be disposed of in the household 

waste. At the end of its service life, dispose of the product according to the relevant 

statutory regulations.

You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Operating voltage ........................................ 230 V/AC, 50 - 60 Hz
Power consumption ..................................... < 0.2 W
Connection power ........................................  Power socket: max. 3680 W (230 V/AC, 16 A) 

USB charging output: max. 10.5 W  

(5 V/DC, 2.1 A for both sockets)

Protection rating .......................................... IP20
Protection class ........................................... I
Enhanced protection 

against accidental contact ........................... yes
Suitable cable cross-section for  

terminal connections ....................................  1.5 - 2.5 mm²
Overload protection for  

USB charging output ................................... yes
Short circuit protection for  

USB charging output ................................... yes
Operating conditions ....................................  -10 to +40 °C, 20 - 90 % RH (non-condensing)
Storage conditions .......................................  -10 to +40 °C, 20 - 90 % RH (non-condensing)
Suitable surface-mounted/ 

flush-mounted box

 ....................................... Ø 60 mm

Installation depth ......................................... 50 mm
Dimensions (W x H x D) .............................. 86 x 86 x 46.4 mm
Weight ......................................................... 107 g
 

Содержание 1425527

Страница 1: ... Schutzschalter und dem Produkt muss sich eine entsprechend dimensionierte Sicherung bzw ein Sicherungsautomat max 16 A befinden Montieren Sie das Produkt nur an einer leicht zugänglichen Position Die Montage und der Anschluss dürfen nur dann erfolgen wenn die Zuleitungen allpolig von der Netzspannung getrennt sind Andernfalls besteht Lebensgefahr durch einen elektrischen Schlag Bedienungsanleitun...

Страница 2: ...soliert werden L 8 Phase N 6 Neutralleiter PE 7 Schutzleiter Soll eine Leitung aus einem Klemmanschluss entfernt werden schrauben Sie die Schraube locker und ziehen Sie dann die Leitung aus dem Klemmanschluss heraus Klicken Sie das Steckdosen Modul 4 in die Montageplatte ein Achten Sie beim Einsetzen des Steckdose Moduls 4 bzw beim Festschrauben darauf dass die Kabel nicht beschädigt werden Platzi...

Страница 3: ...al current circuit breaker A correctly dimensioned fuse e g an automatic fuse max 16 A must be fitted between the residual current circuit breaker and the product Only mount the product in an easily accessible location Only mount and connect the product when the cables have been completely disconnected from the mains voltage otherwise there is a risk of a fatal electrical shock Operating instructi...

Страница 4: ... a wire from a terminal connection loosen the screw and pull the wire out of the connection Click the socket module 4 into the mounting plate Be careful not to damage the cables when inserting the socket module 4 or tightening screws Place the cover frame 3 on the power socket Operation You can connect a standard electrical device to the protective contact power socket on the product i e it functi...

Страница 5: ...schakelaar Tussen FI schakelaar en het product moet zich een dienovereenkomstig grote zekering resp zekeringsautomaat max 16 A bevinden Monteer het product alleen op een goed toegankelijke plek De montage en aansluiting mogen pas dan plaatsvinden als de kabels van alle polen van de netspanning zijn losgekoppeld Anders bestaat levensgevaar door een elektrische schok Gebruiksaanwijzing Contactdoos m...

Страница 6: ...kabel uit de klemaansluiting worden verwijderd dient u de schroef een beetje los te draaien om vervolgens de kabel uit de klemaansluiting te trekken Klik het contactdoosmodule 4 in de montageplaat Let er bij het plaatsen van het contactdoosmodule 4 resp tijdens het vast schroeven op dat de kabels niet beschadigd raken Plaats het afdekframe 3 op de contactdoos Bediening Aan de geaarde contactdoos v...