12
Dimensions
Flow Rate Curve
INSTALLATION
Warning!
Failure to follow instructions can cause damage to the equipment and, in extreme cases, to people.
Warning!
When working on the pump wear the adequate systems of personal protection (gloves, apron, goggles).
-
Install the pump away from heat sources, in a dry place, at a maximum ambient temperature of 45°C. Also prevent that the
pump is exposed to direct sunlight to avoid overheating. The minimum temperature shall be such as to ensure the solution
to be dosed remains in a fluid state.
-
It is recommended to install the pump above the level of the liquid to be dosed, to a maximum height of 1.5 meters
from the bottom of the tank. If the pump is installed below the level of the liquid, periodically check the injection valve.
-
If the pump is placed above the tank and the reagent fumes could be especially aggressive, check the tank seals.
-
These pumps are designed for wall installation, but a special bracket (optional) for horizontal mounting is also
available.
-
To avoid damage of the hydraulic connections, all operations to tighten the pipe on the dosing pump must be
performed by hand, without using any tool.
Note:
If the product to be dosed is SULFURIC ACID, previously remove any water from the pump head and use a
polyethylene suction tube.
Note:
The ON/OFF pump is preconfigured at the factory to work at the maximum frequency.