Manual Drain Button
·
For extended storage or movement of the machine, press the "Drain" button to remove water
from the integral pump’s reservoir.
6
.
Pump Trouble Warning
·
When the pump reservoir water level is too high, the high water sensor will activate to prevent
overflow. When this occurs, the dehumidifier will stop the compressor automatically and the display will
show "E4" error. After a 1 minute delay, the fan motor will turn off and the machine will not operate until
the problem is resolved. To reset the unit after an “E4" error, check the pump to verify it is functioning,
then unplug the unit for two minutes.
7
.
Auxillary Terminals A5
/
A6
·
The A5/A6 on the terminal strip can be used as a safety switch for external condensate pumps. It
should be set to N/O (normally open) at the dehumidifier. If an E4 error codes, switch the wiring to N/C
(normally closed).
5
Indicator
Lights
1
.
Humidity
Display
Screen
·
The
display
screen
has
two
functions
:
1
.
When
the
unit
is
powered
on
,
it
shows
the
humidity
of
the
space
.
2
.
While
setting
the
desired
humidity
level
,
the
screen
will
show
the
set
humidity
.
After
a
brief
delay
,
the
display
will
revert
to
the
current
humidity
level
.
2
.
Power
Indicator
Light
·
This
light
indicates
that
the
unit
is
properly
powered
on
and
ready
to
operate
.
Always
make
sure
the
is
"
off
"
prior
to
performing
any
service
.
3
.
Continuous
Mode
/
AutoDefrost
Light
·
When
this
light
illuminates
green
,
it
indicates
that
the
dehumidifier
is
set
to
continuous
operation
mode
.
·
When
the
light
glows
red
,
it
means
the
unit
is
in
auto
defrost
mode
and
clearing
the
evaporator
coil
of
any
ice
buildup
.