Installation Manual
©
2020
bas
alt
e v
3.
0
Installation instructions
1. Install square wall box (60mm) or compatible round wall box.
Wall box should have screws with a vertical distance of 60mm and minimal depth of 45mm.
2. Connect the 24V DC power lines using the terminals.
3. Fix the wall base to the wall box with 2 screws using the holes on vertical axis.
4. Mount the cover using the clips (see drawing below).
Cabling
The cable between the DC power supply and wall base must have a cable section of at least 0.8mm
2
and
maximum 1.5mm
2
. The applicable maximum cable lengths are specified both 12V and 24V.
To limit power loss in the cable, we recommend using a star wiring from the power supply to each single wall
base. We advise to automatically put the iPad in standby mode when not in use to reduce power consumption.
Maximum cable length between DC power supply and wall base
Cable type
12V DC
24V DC
0.8mm
2
(AWG 19)
50m (164ft)
300m (984ft)
1.0mm
2
(AWG 18)
60m (197ft)
400m (1312ft)
1.5mm
2
(AWG 17)
90m (295ft)
500m (1640ft)
How to remove the Socket front cover
(see drawing below)
EVE PLUS WALL BASE 24V
Technical data
Power supply:
10 - 30 V DC
Consumption:
Input power 15W
Operating temperature:
0°C - +35°C
A
Place the frame over the lower clips
B
Push the frame upwards and tilt towards the wall
C
Attach the frame over the top clips
Pushing the frame straight
into the clips without
pushing upwards and
lifting, might damage the
wall base.
E
Push the frame upwards
F
Tilt the frame away from the wall
a
b
c
e
f
basalte
bv
| hundelgemsesteenweg 1A | 9820 merelbeke | belgium
t +32 (0)9 385 78 38 | f +32 (0)9 329 66 95 | www.basalte.be | [email protected]