Completness check of the product
Before installing the monitor, be sure to check that it is complete and all
components are available.
The kit includes:
Device
Manual
Wall mounting bracket
A set of wires with connectors for connecting alarm loops
and home automation
Resistors for alarm loops
Installation screws
1 pc
1 pc
1 pc
1 pc
4 pcs
2 pcs
After verifying the device's completeness, you can switch to the connection.
To connect monitor you will need:
Electrical connection
An Ethernet UTP CAT5 or higher cable connected to a network
switch
/
router.
Cable length recommendations
The maximum length of the UTP CAT5 cable segment should not exceed 100 meters,
according to the IEEE 802.3 standard.
Power supply at +12 Volts DC if there isn't PoE.
Wires must be brought for the connection of alarm loops and home
automation (optional).
The connection scheme of all components
+
-
+12 Volts DC
Power
LAN (PoE)
1
2
3
4
5
6
+U
GND
AL1
AL2
AL3
AL4
RS 485
1
2
3
4
+12V
GND
485+
485-
Siren/Alarm Loops
EAN: 5060514914953
(BLACK)