BAS-IP SH-47T Скачать руководство пользователя страница 4

After verifying the device's completeness, you can switch to the 

exit button

connection.

Electrical connection

IMPORTANT

   

It is strictly forbidden to supply more than + 12.

2

V to the SH-4

7T

 button.

   Do not load the output contact of the button with a current exceeding
100 mA.
   

It is strictly forbidden to use the SH-4

7T

 button to use the power supply

used to power the lock

.

   

It is necessary to use a separate power supply to which locks and other

high-consumption equipment are not connected

.

Purpose of wires:
    

Red: 

+ 12V (+ 1%, - 15%).

    Black: 

Ground (General).

    Brown: 

Transfer to trigger

mode.

    Green: 

Changes the backlight

color to green.

    Yellow: 

Controlled output.

CONTROLLER

Out

Input

Input

Yellow (-)

Red (+)

Black (-)

Brown (-)

Green (-)