SETTINGS THROUGH THE WEB INTERFACE
AEC Level: AEC Level. Default value is 700.
Photo resistor Settings: Range of photo resistance sensitivity level (0-100). The default values
are 5 - 37.
Tamper Alarm: Alarm on / off function on the tamper.
Accelerometer Trigger Threshold: Accelerometer Trigger Level (0 – 127).
The default value is 32.
Location Setting: Number of building, unit, floor, room, serial number, sync number.
IP server: The IP address of the server with Management Software.
Wiegand Type: The type of used Wiegand interface. It is possible to choose between
Wiegand - 26 and Wiegand - 34.
Blinking Time: The blinking frequency of the ring button LEDs during the lock opening is from
500 ms up to 5000 ms.
2.3 Relay
Select “Relay” to access the configuration of the relay outputs: