background image

Installation and operation  

 

 

850200   

 

 

11 / 18 

EN 

 

Installation and operation 

 

 

5.1

 

Installation 

 

 

Unpacking / Positioning 

•  Unpack the appliance, remove all external and internal packaging elements and 

shipment safeguards. 

  CAUTION! 

Choking hazard! 

Prevent children from accessing package materials, for instance: plastic 
bags and EPS. 

 
•  If the appliance is covered with a protective film, remove it. Remove the film 

slowly, so no glue residues are left. Remove any glue residues with the use of a 
suitable solvent. 

•  Be careful not to damage the rating plate and warning labels fixed on the 

appliance. 

• 

Never

 place the appliance in humid or wet environment. 

•  Place the appliance in a way making the connections easily accessible, so that 

they may be quickly disconnected if such a need arises. 

•  The appliance should be placed on surfaces that are: 

–  even, with sufficient bearing capacity, resistant to water, dry and resistant 

to high temperatures; 

–  sufficiently large, and thus enabling usage of the appliance with no 

problems; 

–  easily accessible; 
–  well ventilated. 

 

•  Maintain sufficient clearance from table edges. The appliance might turn over 

and fall down. 

 

 

Power supply connection 

•  Verify if technical data of the appliance (see rating plate) correspond with the 

local electric power grid specification. 

•  Connect the appliance to a single, properly grounded mains socket with 

protective contact. Do not connect the appliance to a multi-socket. 

•  The power cord should be laid in a way preventing anyone from threading on it 

or tripping against it. 

Содержание W4000

Страница 1: ...W4000 850200...

Страница 2: ...Bartscher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Service hotline 49 5258 971 197 www bartscher com Version 1 0 Date of preparation 2021 03 15 EN...

Страница 3: ...6 2 3 Declaration of Conformity 6 3 Transport Packaging and Storage 7 3 1 Delivery Check 7 3 2 Packaging 7 3 3 Storage 7 4 Technical Data 8 4 1 Technical Specifications 8 4 2 List of Components of th...

Страница 4: ...included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the area the...

Страница 5: ...nt Too high a mains voltage or incorrect installation may cause electric shock The appliance may be connected only if data on the rating plate correspond with the mains voltage To avoid short circuit...

Страница 6: ...ng children with limited physical sensory or mental capabilities nor by persons with limited experience and or limited knowledge Children should be supervised to ensure that they are not playing with...

Страница 7: ...rohibited and considered to be an unintended use The following is an intended use For use in living areas restaurants hotels and offices 1 4 Unintended Use An unintended use may lead to personal injur...

Страница 8: ...troduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2 Copyrigh...

Страница 9: ...used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Particularly...

Страница 10: ...d load 0 05 kW 110 240 V 50 60 Hz Dimensions W x D x H in mm 300 x 270 x 562 Weight in kg 4 8 We reserve the right to implement technical modifications Version Characteristics Designed for rooms up to...

Страница 11: ...Technical Data 850200 9 18 EN 4 2 List of Components of the Appliance Fig 1 1 Ventilation openings 2 Protective shield 3 Light ring 4 Control panel 5 Ventilation 6 Motor 7 Filter 8 Housing...

Страница 12: ...1 Digital display 2 UV indicator light 3 Time setting key 4 UV lamp key 5 ON OFF key 6 Operating mode key 4 3 Functions of the Appliance The room air cleaner is designed for removal of pollution from...

Страница 13: ...e in a way making the connections easily accessible so that they may be quickly disconnected if such a need arises The appliance should be placed on surfaces that are even with sufficient bearing capa...

Страница 14: ...nto a suitable single socket Starting up Adjustment 1 Switch the appliance on with the ON OFF key The appliance starts after 30 seconds The light ring is lit in green or lilac during start up When the...

Страница 15: ...the power supply Leave the appliance to cool down completely Make sure water does not enter the appliance Do not immerse the appliance in water or other liquids during cleaning Do not clean the applia...

Страница 16: ...at the rear wall of the appliance to remove the rear wall 3 Remove the filter 4 Take a new filter out of its packaging To order the filter use art No 850210 5 Insert the new filter in the appliance 6...

Страница 17: ...Change filter Appliance evidences poor performance Filter surface is polluted Clean the filter surface Air inlet outlet obstructed Clean the air inlet outlet The appliance generates loud sounds Foreig...

Страница 18: ...ot open the housing inform the service company or contact the supplier and provide the following data type of malfunction code number and serial number to read from the rating plate of the device 8 Di...

Отзывы: