Bartscher Thermometer 480 Скачать руководство пользователя страница 3

 

 

 
 

Instructions for use 

 

The thermometer is a touch-free infrared thermometer equipped with a needle 
thermal sensor. It can only function in one mode at a time, but those modes can 
be switched as desired. 

 

Pressing the begin infrared measurement button 

: immediately activates 

the touch-free infrared thermometer function (IRT mode).  

 

Pressing the begin needle sensor measurement button 

: immediately 

activates the contact thermometer function (COT mode).  

 

 

 

To switch directly from COT mode to IRT mode, press 

button 

 when COT is in "Standby mode (Hold)".

 

 
 

  

 Needle sensor 

 

 Mode 

 Infrared Lens 

     

 Infrared 

measurement 
 

 Needle 

measurement 

 

 Begin 

measurement 
(infrared) 

 

     

 Begin   

 measurement 
(needle sensor) 
 

 Clip 

Содержание Thermometer 480

Страница 1: ...Thermometer 480 infrared for measuring surface temperature and internal temperature 292 480 GB UK ...

Страница 2: ...6 F 55 to 330 C Precision 2 F 1 C or 1 of measurement depending on greater value Definition 0 1 F 0 1 C switched Battery CR2032 Description on front of packaging Dual Temp Infrared Thermometer with needle sensor Touch free infrared thermometer for measuring surface temperatures Collapsible thermal needle sensor for measuring internal temperature Min max memory function Stay on function for longer ...

Страница 3: ...rement button immediately activates the touch free infrared thermometer function IRT mode Pressing the begin needle sensor measurement button immediately activates the contact thermometer function COT mode To switch directly from COT mode to IRT mode press button when COT is in Standby mode Hold Needle sensor Mode Infrared Lens Infrared measurement Needle measurement Begin measurement infrared Beg...

Страница 4: ...ermometer will display the minimum or maximum value until button is pressed To activate minimum mode press Press button to begin measurement To activate maximum mode press twice Press button to begin measurement Stay on function The stay on function is useful for measuring temperatures over longer periods of time The thermometer displays the temperature constantly for a period of up to 60 minutes ...

Страница 5: ...he object being measured and press to display the temperature for up to 4 minutes After this time the unit will turn off automatically to save battery power Pressing will stop the measurement and display the last temperature along with the message Hold To resume measurement press again 1 Do not bend or rotate the needle sensor in the wrong direction 2 Placing too much pressure on the sensor may ca...

Страница 6: ...ermometer turn the unit off remove the battery and wait at least one minute before replacing the battery and turning the unit on If the error message continues to display contact your customer service agent BATTERY The thermometer is equipped with a batter charge indicator Sufficient battery charge Low battery charge Empty battery Measurements can be taken Battery should be replaced soon but measu...

Страница 7: ...e Battery use 30 hours of continuous functioning auto off after 15 seconds Dimensions W 33 x D 22 x H 160 mm Weight 2 6 oz 74 g with battery EMC RFI Measurements and readings can be affected if the unit is used in the vicinity of strong high frequency electromagnetic fields e g radio frequencies with a field strength of approx 3 Volts m but this has no long term effect on the measurement strength ...