Installation Instructions
110645
17 / 32
EN
ATTENTION!
Following installation, the installer must issue a written statement and
confirm that the installation and commissioning test have been conducted
correctly and professionally, pursuant to statutory provisions in force in
the installation location.
Klars Kl
5.6
Rinsing Agent Dosing Pump and Cleaning Agent Dosing
Pump
The appliance is equipped with the
rinsing agent dosing pump
. Thanks to this
dosing device, the appropriate quantity of rinsing agent is added to the wash-tank
each time.
Located at the rear of the appliance, the hose with marking for rinsing agent should
be introduced to the rinsing agent tank.
The hoses are transparent, thus the introduced chemical compounds are always
visible.
Operation method:
Thanks to this dosing device, the liquid rinsing agent is
supplied whenever a drop in pressure is detected during rinsing. This happens
when the filling valve is closed. As an outcome, underpressure is generated, which
causes the liquid to be sucked by the rinsing agent dosing device.
Setting: this dosing device should be set up during the installation, because this is
the only way the user may use all washing features in an optimum way from the
very beginning. The setting must be properly adjusted depending on the selected
rinsing agent and hardness of the available water.
NOTE:
A selection of the rinsing agent and setting of the rinsing agent dosing
pump should be ordered with a qualified technician who has experience
with chemical products, to achieve the most efficient washing effects.
The appliance is equipped with the washing agent dosing pump. Thanks to this
dosing device the appropriate quantity of washing agent is added to the wash-tank
each time.
Located at the rear of the appliance, the hose with marking for washing agent
should be introduced to the washing agent tank.
Operation method
: The washing agent dosing pump is activated when the
appliance collects water during washing or filling process.
Setting
: The quantity of washing agent should be set during the installation at the
washing agent dosing pump, so that the user may use all washing features in an
optimum way from the very beginning.
The hose in the washing agent dosing pump must be replaced annually.