CAREFULLY  READ  THE  INSTRUCTIONS  CONTAINED  IN  THIS  MANUAL  SINCE  THEY 

PROVIDE  IMPORTANT  INFORMATION  RELATIVE  TO  SAFETY  DURING  INSTALLATION, 

USE, AND MAINTENANCE. 

 

EDITION: 

NOVEMBER 2001. 

COD: QU02MTIN.DOC 

 
 

GB/UK

104203

104205

104208

104215

Содержание QUASAR 90 C

Страница 1: ...C QUASAR 50 C QUASAR 60 C QUASAR 90 C QUASAR 130 C QUASAR 150 C MODULARS MQ 200 CAREFULLY READ THE INSTRUCTIONS CONTAINED IN THIS MANUAL SINCE THEY PROVIDE IMPORTANT INFORMATION RELATIVE TO SAFETY DUR...

Страница 2: ...nd serial number 13 Installation Recommended placement of unit 14 Water and drainage 14 Connecting unit to water source 15 Connecting unit to drain 15 Electrical connection 15 Operation principle Prel...

Страница 3: ...than specially trained technicians is extremely dangerous and may result in a fire or electric shock This machine should not be placed outdoors or exposed to rain Connect to drinking water mains This...

Страница 4: ...eight and diameter Easy to maintain and repair HOW IT WORKS When the machine is switched on the compressor and the agitator motor start the water entry valve opens and allows water into the production...

Страница 5: ...full the pan stops in its downward movement as it touches the cubes so working the safety stop micro switch and switching off the machine Production will start again as soon as the cubes which detain...

Страница 6: ...6...

Страница 7: ...R 20 C 405 510 690 60 35 65 123 45 65 105 QUASAR 30 C 405 510 745 60 35 65 123 45 65 105 QUASAR 40 C 405 510 870 60 35 65 123 45 65 105 QUASAR 40S 50 C 515 555 870 60 42 74 123 65 75 105 QUASAR 60 C 5...

Страница 8: ...8 STOCK THERMOSTAT WATER INLET ELECTRICAL CONNECTION...

Страница 9: ...VERAGE 2 1 2 GR Kg cm2 Psi Kg cm2 Psi Kg cm2 Psi A A W W QUASAR 20C A 260 16 228 17 240 2 5 38 1 5 10 175 220 QUASAR 20C W 190 16 228 17 240 2 5 38 1 5 10 175 220 QUASAR 30C A 260 16 228 17 240 2 5 38...

Страница 10: ...0 5 22 38 24 37 25 35 26 33 28 32 29 31 25 41 27 40 29 38 31 36 32 34 33 31 33 5 30 25 20 42 21 40 5 22 38 24 37 25 35 26 33 28 32 24 43 25 41 27 40 29 38 31 36 32 34 33 31 20 19 44 20 42 21 40 5 22 3...

Страница 11: ...0 35 WATER TEMPERATURE C Water quality 500 ppm 240 Micromh cm QUASAR 150 C 45 24 99 26 92 28 85 29 81 30 79 31 77 32 74 40 23 103 24 99 26 92 28 85 29 81 30 79 31 77 35 22 108 23 103 24 99 26 92 28 85...

Страница 12: ...r on all claims Serial number is located in the following three places Packing There is a label stick onto the cardboard packing bearing this serial number 1 Machine body On the machine s rear panel 1...

Страница 13: ...ations if the premises where the machines is located are very dusty or smoky If possible make arrangements so that the machine may be moved front wise in order to carry out maintenance Recommended Pla...

Страница 14: ...proper function In water cooled models condenser obstruction is likely Installation of a high quality water softener is recommended c CHLORINATED WATER Chlorine taste can be avoided by installing a c...

Страница 15: ...pply Machine levelling Place machine where it is required and level the machine ONCE all four legs have been screwed on Space requirements There should be a 150 mm gap on sides and top of the machine...

Страница 16: ...ater pressure adequate MAXIMUM 0 7 Kg cm2 MINIMUM 6 Kg cm2 ATTENTION Check that voltage and mains frequency are the same as in the rating plate Starting up Once preliminary check has been completed ve...

Страница 17: ...28 Psi which is equivalent to a water exit temperature of 38 C below this pressure it will be difficult to unstick the cubes in the defrosting stage Above this pressure compressor life and ice product...

Страница 18: ...nish ice production Pressure can be regulated by rotating screw on Pressure Control Valve clockwise to increase pressure One rotation equals 1 5 Kg cm2 Safety pressostat This Security device trips whe...

Страница 19: ...mplete procedures on a monthly basis MAINTENANCE TABLE PROCEDURE MONTHLY QUARTERLY BIANNUAL YEARLY BIENNIAL DURATION Air condenser cleaning 0000 0000 30 minutes Water condenser cleaning 90 minutes Wat...

Страница 20: ...istribute solution through condenser Solution is more effective at 35 40 C WARNING DO NOT USE HYDROCHLORIC ACID Air Condenser 1 Disconnect machine 2 Close water faucet 3 Clean condenser using a vacuum...

Страница 21: ...t 5 minutes 9 Repeat 6 several times until water pan has been thoroughly rinsed WARNING Discard ice produced during cleaning procedure Cleaning the ice bin 1 Unplug the machine turn off water supply a...

Страница 22: ...arate Always use the liquid phase valve at the end of condenser or accumulator for refills and purges When replacing a compressor wash inside of circuit with a suitable solvent pump dry with nitrogen...

Страница 23: ...ace Klixon D Faulty compressor D Replace compressor 3 All the electrics work but the compressor Klixons cycles intermittently A Voltage too low A Check voltage B Dirty condenser B Clean condenser C Ob...

Страница 24: ...n or pressostat faulty inlet cooling water valve D Check fan and re adjust pressostat or replace E Refrigerant charge too high or too low E Adjust F Faulty water inlet valve leaks and does not close f...

Страница 25: ...tor micro switch badly connected or faulty A Connect or replace micro switch B Security micro badly connected or faulty B Connect or replace micro switch C Faulty rele C Replace rele 13 The evaporator...