13
INSTALLATION
The ice cube maker is delivered on a small wooden pallet and is protected with a cardboard box and packaging. Loosen the cardboard
box by cutting the straps, then lift vertically.
After having removed the packaging, make sure the machine is complete. If in doubt do not use it and go to the
distributor who sold it to you.
This operation has to be performed with the wooden base structure firmly placed on the ground. All packaging
elements (plastic bags, cartons, etc..) must not be left at children's reach, since they are a potential source of
danger.
Place the machine where it is to be installed, and verify, using a level control, that the machine is in a horizontal
position.
CAUTION:
If the gap between the back of the machine and the wall of the room/bar is not sufficient, or if it is going to receive
hot air from another machine, we strongly advise, in case of not being able to change the location of the machine,
to
INSTALL A WATER-COOLED MACHINE.
Bear in mind the previous considerations if the premises where the machines is located are very dusty, or smoky. If
possible make arrangements so that the machine may be moved front-wise in order to carry out maintenance.
Recommended Placement of Unit
QUASAR machines are intended to operate at room temperature between 5°C and 43°C and with water
temperature ranging between 5°C and 35°C. Below recommended minimum temperatures, ice cubes will be
un-stick correctly and may form a slab or block of ice. Operation carried out over maximum recommended
temperatures can result in shorter compressor life and decreased production.
Air-cooled units receive air input via front of machine and expel air through rear grill.
IMPORTANT!
If front and/or rear ventilation is inadequate, obstructed, or in close proximity to other heat producing
machinery, USE OF A WATER-COOLED UNIT is strongly recommended.
Water inlet tube should not pass near heat sources: water entering the machine should be as cold as possible,
but always above 5ºC.
The above mentioned also applies should unit be installed in an area where dust, smoke, or other airborne
pollutants may be present. Units—especially air-cooled—should not be installed in kitchens. To facilitate
Содержание QUASAR 130 C
Страница 6: ...6 ...
Страница 8: ...8 STOCK THERMOSTAT WATER INLET ELECTRICAL CONNECTION ...