background image

 

Installation and operation 

18 / 26   

 

 

 

125543-125543V1-125543V2 

EN 

LED Indicators 

The LED indicators in the digital display show the status of the active function: 
 

 

LED 

Status of the 
active function 

Meaning 

 

illuminates 

the compressor is running (K1 output relay is on, 
Act = 0)  

flashes 

during compressor start delay 

 

illuminates 

the heater is working (the K1 output relay is on, 
Act = 1)  

flashes 

during the heater delay time 

 

illuminates 

defrosting in progress 

flashes 

during the delay after defrost 

 
The upper left point flashes in programming mode and lights when the external 
contact (digital input) is active or in Standby mode.  

The number "1" that appears on the digital display shows the current temperature of 
the sensor. 
 

 

Setting the temperature (required value) 

1.  Press the 

 

button once for a moment. 

The digital display shows “SET”. The upper point to the left of the temperature 
gauge is flashing to indicate entering programming mode. 

2.  To display the set value, press the 

 

button again. 

3.  To set the required set value, press the 

 or 

 button within 15 seconds.  

4.  Press the 

 button to confirm the set data. 

NOTE! 

If this button is not operated for more than 15 seconds (Timeout) or when 

the 

 button is pressed once, the last value shown on the display will be 

adopted and the previous message will be displayed again. 

 

Automatic Defrosting 

The appliance defrosts automatically 4 times over a 24-hour period. The timer 
initiates with the first activation.  

Содержание K3110-200U

Страница 1: ...K3110 200U 200W 200A K4110 200U 200W 200A 125543 125543V1 125543V2 125544 125544V1 125544V2...

Страница 2: ...scher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Technical Support Hotline 49 5258 971 197 www bartscher com Version 1 0 Date of preparation 2021 10 08...

Страница 3: ...2 Copyright Protection 7 2 3 Declaration of Conformity 7 3 Transport Packaging and Storage 8 3 1 Delivery Check 8 3 2 Packaging 8 3 3 Storage 8 4 Technical Data 9 4 1 Technical Specifications 9 4 2 Fu...

Страница 4: ...structions included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the...

Страница 5: ...cal Current Too high a mains voltage or incorrect installation may cause electric shock The appliance may be connected only if data on the rating plate correspond with the mains voltage To avoid short...

Страница 6: ...e pull the plug from the socket Remove all sources of ignition in the vicinity ventilate room and contact technical service Avoid coolant getting in contact with eyes as it may cause serious eye damag...

Страница 7: ...peration The appliance may only be used when all connections are executed according to rules of law in force The appliance may only be used when it is clean Use only original spare parts Never attempt...

Страница 8: ...4 Unintended Use An unintended use may lead to personal injuries or property damages caused by hazardous voltage fire or high temperature The appliance may only be used to perform tasks described in...

Страница 9: ...ations introduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2...

Страница 10: ...It may be used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Par...

Страница 11: ...plug is inserted Drain tap checking of power cord spiral cable cord length 1 m Swivel castors 5 swivel castors 2 with brakes Indicator light ON OFF State at delivery assembled for ready to use Stainle...

Страница 12: ...racite Number of slits 1 Basin size GN format 3 x 1 1 GN Max GN container depth in mm 200 Temperature range min max in C 2 4 Climate class 3 Coolant amount in kg R290 0 07 Dimensions of the shelf for...

Страница 13: ...4 Climate class 3 Coolant amount in kg R290 0 07 Dimensions of the shelf for moving trays W x D in mm 1 495 x 250 Number of bars 4 Bar dimensions W x D in mm 528 x 30 Power supply 0 349 kW 230 V 50 H...

Страница 14: ...er indicator light green 2 Digital temperature controller 3 LED lighting button 4 LED lighting 5 Hygienic cover bracket 6 Sneeze guard 7 Shelves for moving trays 2 pcs 8 Cooling tray for GN containers...

Страница 15: ...lowly so no glue residues are left Remove any glue residues with the use of a suitable solvent Be careful not to damage the rating plate and warning labels fixed on the appliance Never place the appli...

Страница 16: ...earance from walls and other objects To install the appliance perform the following steps Remove the packaging of the appliance except for the pallet Lift the appliance with the lift truck and move it...

Страница 17: ...tor Use the data in the table below to determine the storage temperatures The given temperatures in accordance with the HACCP regulation are approximate values and may change depending on the environm...

Страница 18: ...FF push button The green power indicator light in the ON OFF switch lights up When the appliance is switched on the indicator lights test is carried out the digital temperature controller and the LED...

Страница 19: ...lues Esc command 4 during an alarm event to disable the optional internal buzzer and relay Enter key 1 Programming Mode Activation 2 View and confirm new setting values Setting value decrease button 1...

Страница 20: ...de The number 1 that appears on the digital display shows the current temperature of the sensor Setting the temperature required value 1 Press the button once for a moment The digital display shows SE...

Страница 21: ...after 6 hours Manual Defrosting Additionally aside of the automatic defrosting manual defrosting may be activated 1 Press and keep the button pressed for over 5 seconds The manual defrosting is initi...

Страница 22: ...rm data are stored the message AL1 min max reached temperature and its duration in minutes appears when temperature 1 was above ALo or AHi next AL2 min max alarm appears AL1 refers to the most recent...

Страница 23: ...s an internal buzzer and an alarm relay if available optional AtP 0 50 AHi 1 AtP 1 50 0 5 C 40 C AHi Alarm when the temperature is exceeded ex HiA If the temperature raises above this value ALo 0 4 th...

Страница 24: ...ointed implements may damage the appliance and when in contact with live parts they may cause electric shock For cleaning do not use any scouring agents that contain solvents nor corrosive cleaning ag...

Страница 25: ...dry it thoroughly 6 Only clean laminated wooden surfaces with a slightly damp cloth For stubborn stains use a little alcohol 7 Clean the GN container in use thoroughly with running hot water a soft cl...

Страница 26: ...ect and environmentally friendly manner You must not dispose of electric appliances with household waste Disconnect the appliance from the power supply and remove power cord from the appliance Electri...

Отзывы: