background image

Manuale d’istruzione per l’installazione, la manutenzione e l’uso 

Pentole elettriche Indirette  

01.08.01 - IT 

pagina 

 

12

 

 

INDEX 

Part 1: General reminders and notes 

1.1. 

General reminders 

13 

1.2. 

Technical data 

13 

1.3. 

Construction 

14 

1.3.1. 

Details only for pressure kettles 

14 

1.4. 

Laws, technical prescriptions and directives 

14 

1.5. 

Special requirements for the installation site 

15 

Part 2: Positioning, installation and maintenance 

2.1. 

Positioning 

15 

2.2. 

Installation 

15 

2.2.1. 

Electrical connections and equipotential bonding 

16 

2.2.2. 

Connection to waterworks 

16 

2.3. 

Commissioning and testing 

16 

2.4. 

Maintenance of the appliance 

17 

2.4.1. 

Possible failures and their elimination  

17 

Part 3: Use and cleaning 

3.1. 

Warnings and hints for user 

17 

3.2. 

Instructions for use 

18 

3.2.1. 

Filling the jacket  

18 

3.2.2. 

Details regarding the operation of the pressure kettles 

18 

3.2.3. 

Switch on, start of cooking and switch off 

19 

3.3. 

Cleaning and care of the appliance 

19 

3.3.1. 

Daily cleaning 

19 

3.4. 

Special procedures in case of long inactivity 

20 

3.5. 

Special procedures in case of failures 

20 

3.6. 

How to proceed, if … 

20 

Part 4: Figures and details 

4.1. 

Wiring diagram Mod. 100-150 lt. 3N/PE AC 400V 

52 

4.1.1. 

Wiring diagram Mod. 100-150 lt. 3/PE AC 230V 

54 

4.1.2. 

Wiring diagram Mod. 100-150 lt. 3/PE AC440V 

55 

4.1.3. 

Wiring diagram Mod. 100-150 lt. 3/PE AC480V 

56 

4.2. 

View of appliance  

57 

4.3. 

Controls 

58 

 

Содержание 9PEN1

Страница 1: ...stallazione la manutenzione e l uso Pentole elettriche Indirette 01 08 01 IT pagina 11 INSTRUCTION MANUAL FOR INSTALLATION MAINTENANCE AND USE ELECTRIC KETTLES INDIRECT SERIE 900 9PEN1 9PEN1A 9PEN2 9PEN2A 296910 296911 01 08 01 GB ...

Страница 2: ... 16 2 4 Maintenance of the appliance 17 2 4 1 Possible failures and their elimination 17 Part 3 Use and cleaning 3 1 Warnings and hints for user 17 3 2 Instructions for use 18 3 2 1 Filling the jacket 18 3 2 2 Details regarding the operation of the pressure kettles 18 3 2 3 Switch on start of cooking and switch off 19 3 3 Cleaning and care of the appliance 19 3 3 1 Daily cleaning 19 3 4 Special pr...

Страница 3: ...xclusively to a service centre for repairs or maintenance Any important information about the appliance required for technical service is contained in the technical data plate see figure View of appliance If technical assistance is required the trouble must be described in as much detail as possible so that a service technician will be able to understand the nature of the problem Gloves should be ...

Страница 4: ...d with a three position selector with three heating functions position 0 Heating not activated position 1 Reduced power 50 position 2 Full power 100 Operating thermostat for temperature adjustment inside the cooking vat 1 3 1 DETAILS ONLY FOR PRESSURE KETTLES Stainless steel lid with heat resistant silicone gasket Hermetic closing of lid ensured by 4 screw clamps The relief valve for the pressure ...

Страница 5: ...e damage do not connect the appliance and notify the sales point immediately Remove the PVC protection from the panels Dispose of packaging according to regulations Generally material is divided according to composition and should be delivered to the waste disposal service There are no special instructions regarding distances from other appliances or walls however it is advisable to maintain a suf...

Страница 6: ...mm 2 All the appliances installed and the earth system of the building shall be connected like this 2 2 2 CONNECTION TO WATERWORKS Water inlet pressure must be between 50 and 300 kPa otherwise install a pressure regulator on the line before the appliance Install a cut off valve for each supply on the line before the appliance Water connections to 10 mm are fitted in the lower part on the right han...

Страница 7: ...h failure Safety thermostat The safety thermostat can be reached once the lower front panel has been removed Heating elements The heating elements can be reached once the lower front panel has been removed Selector switch Operating thermostat To reach remove the upper front panel 3 1 WARNINGS AND HINTS FOR USER This manual contains all the instructions required for a proper and safe use of our app...

Страница 8: ...nnections Fill with softened water the capacity of the jacket is stated in the paragraph Technical data Check the water level by looking through the hole on the left of the front panel of the appliance Screw back on the cap of the safety device 3 2 2 DETAILS REGARDING OPERATION WITH PRESSURE KETTLE Before turning the appliance on close the lid firmly and lock the 4 screw clamps Check that the valv...

Страница 9: ...over the temperature of 100 C Heating elements operate continuously By turning the selector from position 2 to 1 it is possible to keep the water boiling and use less power 3 3 CLEANING AND CARE OF THE APPLIANCE Do not use aggressive substances or abrasive detergents when cleaning the stainless steel components Avoid using metal pads of the steel parts as they may cause rust For the same reason av...

Страница 10: ...ufacturer shall not be held responsible nor has any warranty commitments for damage caused by non compliance with prescriptions or by installation not in conformity with instructions The same applies in case of improper use or different application by the operator 3 6 HOW TO PROCEED IF Warning Problems and failures may occur even when the appliance is used properly Here is a list of the mist proba...

Страница 11: ...ligne S1 Electrovanne chargement double paroi OPTIONAL F1 Fusible 3 15 A T TS Thermostat de sécurité SE Sélecteur TL Thermostat de travail L1 Lampe témoin verte de tension C1 Télérupteur minimum L2 Témoin lumineux chauffage C2 Télérupteur maximum LR Lampe témoin orange riserve H20 double paroi C3 Télérupteur de sécurité LA Lampe témoin rouge alarme manque H20 doubler paroi R1 Résistance 230V SL Fi...

Страница 12: ...Manuale d istruzione per l installazione la manutenzione e l uso Pentole elettriche Indirette 01 08 01 IT pagina 53 ...

Страница 13: ... min B Sensor for safety thermostat C2 Electromagnetic switch max 4 1 1 SCHEMA ELECTRIQUE MOD 100 150 LT 3 PE AC 230V LEGENDE mA Bornier arrivée ligne C3 Télérupteur de sécurité F1 Fusible 3 15 A T R1 Résistance 230V C1 Télérupteur minimum B Bulbe pour thermostat securite C2 Télérupteur maximum 4 1 1 ELEKTRISCHER SCHALTPLAN MOD 100 150 LT 3 PE AC 230V LEGENDE mA Netzanschlußklemme C3 Schaltschütz ...

Страница 14: ...agnetic switch min B Sensor for safety thermostat 4 1 2 SCHEMA ELECTRIQUE MOD 100 150 LT 3 PE AC 440V LEGENDE mA Bornier arrivée ligne C2 Télérupteur maximum F1 Fusible 3 15 A T C3 Télérupteur de sécurité TR Transformateur 440 480 230V R1 Résistance 254V C1 Télérupteur minimum B Bulbe pour thermostat securite 4 1 2 ELEKTRISCHER SCHALTPLAN MOD 100 150 LT 3 PE AC 440V LEGENDE mA Netzanschlußklemme C...

Страница 15: ...agnetic switch min B Sensor for safety thermostat 4 1 3 SCHEMA ELECTRIQUE MOD 100 150 LT 3 PE AC 480V LEGENDE mA Bornier arrivée ligne C2 Télérupteur maximum F1 Fusible 3 15 A T C3 Télérupteur de sécurité TR Transformateur 440 480 230V R1 Résistance 277V C1 Télérupteur minimum B Bulbe pour thermostat securite 4 1 3 ELEKTRISCHER SCHALTPLAN MOD 100 150 LT 3 PE AC 480V LEGENDE mA Netzanschlußklemme C...

Страница 16: ... Kochgutablaßhahn Grifo de descarga de la cuba de cocción A Attacco acqua calda Hot water connection Raccord eau chaude Warmwasseranschluß Empalme agua caliente 2 Rubinetteria carico acqua in vasca Vat water feed tap Robinet de charge eau en cuve Wasserzulaufhahn Kesselfüllung Grifo de carga del agua en la cuba B Attacco acqua fredda Cold water connection Raccord eau froide Kaltwasseranschluß Empa...

Страница 17: ...uncionamiento 5 Lampada spia arancione riserva H20 intercapedine Orange lamp warning light failing water in the jacket Lampe témoin orange riserve H20 double paroi Wasser riserve Orange Signalleuchte Luz testigo anaranjada reserva H2O doble pared 6 Lampada spia rossa allarme mancanza H20 intercapedine Red lamp warning light in the jacket Lampe témoin rouge alarme manque H20 double paroi Rot Signal...

Страница 18: ...ent pour modèles autoclaves Nur für Druckkessel Sólo para modelos autoclave Posizioni della leva della valvola di sfiato Valve and position of relief valve Position du levier de la soupape de soupirail Gebrauchsventil und Stellung des Ventilhebels Válvula y posiciones de la palanca de la válvula de desfogue Valvola aperta Open valve Valvola chiusa Closed valve Soupape ouverte Ventil in Soupape fer...

Отзывы: