Installation Instructions
20 / 26
284403
EN
Connection
— Electrical Power
• Verify if the technical specification of the appliance (see the rating plate)
corresponds to the characteristics of the local electric mains grid.
• The power cord should be laid in a way preventing anyone from threading on it
or tripping against it.
• A circuit breaker of sufficient capacity to disconnect all poles from the power
supply must be installed upstream of the appliance, in an easily accessible
place; its contact opening width must ensure complete separation according to
overvoltage category III, in accordance with the installation regulations. The
maximum permissible leakage current of the appliance is 1 mA/kW.
• Flexible, oil-resistant rubber hoses type H05RN-F or H07RN-F must be used for
connection. Cord cross-section is stated in the technical data table.
• Connect the power cord to the terminal block according to the wiring diagram
supplied with the unit.
• Secure the part of the power cord outside the appliance with a metal tube or
rigid plastic hose.
• In the event of damage to the power cord, have it repaired by the manufacturer,
service company or a professional to exclude any risk.
• Connect the electrical appliance to a working earthing.
• Connect the protective conductor to the terminal marked with the earth symbol
next to the input terminal block.
• Connect the metal structure of the electrical appliance to a protective
equipotential bonding device.
• Connect the conductor to the terminal marked with the equipotential bonding
symbol on the outside of the bottom of the appliance.
• This symbol indicates that the appliance must be integrated into the
equipotential bonding system and connected in accordance with applicable
regulations.
• Do not use the appliance with an external timer or remote control.