Possible Malfunctions
24 / 26
700415
EN
Error
Possible Cause
Solution
Temperature inside
the appliance is too
high / too low
Too little clearance between
objects inside the appliance
Provide for sufficient
clearance between objects
inside the appliance
Appliance is overloaded
Reduce the number of stored
objects
Incorrectly set temperature
controller
Set the temperature control
correctly
Noise level of the
appliance rises
Appliance is not placed on
an even surface
Place the appliance on an
even surface
Loose nuts/screws
Tighten nuts/screws
Appliance touches walls or
other objects
Keep sufficient clearance
from walls or other objects
Objects in the appliance in
contact with each other
Provide for sufficient
clearance between objects
Alarms and prompts
In the case of the alarm, the proper prompt flashes on the digital display,
interchangeably with the temperature value; also, the buzzer and the alarm replay
(if available) may be activated.
All alarms go off automatically (i.e. alarm prompt is stopped, when the cause for the
alarm is eliminated; only the 'CHt' alarm must be confirmed manually through
switching off and on again of the appliance with the use of
button or
disconnection from the mains supply).
When pressed, the
button switches off the buzzer; but the displayed alarm
code and the alarm relay are deactivated only when the cause of the alarm is
eliminated. The available alarm codes are listed in Table 3 below.
Alarm
Code
Buzzer and
Alarm Relay
LED
Description
RESET
E0
Active
ON
Sensor 1 error =
regulation
Automatically
E1
Inactive
ON
Sensor 2 error =
defrosting
Automatically
E2
Inactive
ON
Sensor 3 error =
condenser / product
Automatically
Содержание 700 GN211
Страница 1: ...700 GN211 1400 GN211 700415 700416 ...